MK60DX256ZVLL10 Freescale Semiconductor, MK60DX256ZVLL10 Datasheet - Page 15

KINETIS 256KFLEX ENET

MK60DX256ZVLL10

Manufacturer Part Number
MK60DX256ZVLL10
Description
KINETIS 256KFLEX ENET
Manufacturer
Freescale Semiconductor
Datasheets

Specifications of MK60DX256ZVLL10

Processor Series
K60
Core
ARM Cortex M4
Data Bus Width
16 bit
Program Memory Type
Flash
Program Memory Size
256 KB
Data Ram Size
128 KB
Interface Type
USB, CAN, SPI, I2C, UART
Maximum Clock Frequency
100 MHz
Number Of Programmable I/os
2
Number Of Timers
2
Operating Supply Voltage
1.71 V to 3.6 V
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Package / Case
LQFP-100
Operating Temperature Range
- 40 C to + 105 C
Processor To Be Evaluated
MK60DX256ZVLL10
Supply Current (max)
185 mA
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MK60DX256ZVLL10
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
1. Measured at VDD=3.6V
2. Measured at V
3. Measured at V
5.1.4 Power mode transition operating behaviors
All specifications except t
assume this clock configuration:
Freescale Semiconductor, Inc.
Symbol
Symbol
• CPU and system clocks = 100 MHz
• Bus clock = 50 MHz
• FlexBus clock = 50 MHz
• Flash clock = 25 MHz
t
I
R
R
I
POR
OLT
I
I
OZ
IN
IN
PU
PD
Output low current total for all ports
Input leakage current (per pin) for full temperature
range
Input leakage current (per pin) at 25°C
Hi-Z (off-state) leakage current (per pin)
Internal pullup resistors
Internal pulldown resistors
After a POR event, amount of time from the point V
reaches 1.71 V to execution of the first instruction
across the operating temperature range of the chip.
RUN → VLLS1 → RUN
RUN → VLLS2 → RUN
RUN → VLLS3 → RUN
Description
Description
DD
DD
• RUN → VLLS1
• VLLS1 → RUN
• RUN → VLLS2
• VLLS2 → RUN
• RUN → VLLS3
• VLLS3 → RUN
Table 4. Voltage and current operating behaviors (continued)
supply voltage = V
supply voltage = V
Table 5. Power mode transition operating behaviors
K60 Sub-Family Data Sheet Data Sheet, Rev. 5, 5/2011.
POR
DD
DD
, and VLLSx→RUN recovery times in the following table
min and Vinput = V
min and Vinput = V
Table continues on the next page...
Preliminary
SS
DD
DD
Min.
Min.
20
20
123.8
Max.
TBD
Max.
49.3
49.2
100
300
4.1
4.1
4.1
50
50
1
1
Unit
Unit
mA
μA
μA
μA
μs
μs
μs
μs
μs
μs
μs
Notes
Notes
General
1
1
2
3
1
15

Related parts for MK60DX256ZVLL10