MK60DX256ZVLL10 Freescale Semiconductor, MK60DX256ZVLL10 Datasheet - Page 9

KINETIS 256KFLEX ENET

MK60DX256ZVLL10

Manufacturer Part Number
MK60DX256ZVLL10
Description
KINETIS 256KFLEX ENET
Manufacturer
Freescale Semiconductor
Datasheets

Specifications of MK60DX256ZVLL10

Processor Series
K60
Core
ARM Cortex M4
Data Bus Width
16 bit
Program Memory Type
Flash
Program Memory Size
256 KB
Data Ram Size
128 KB
Interface Type
USB, CAN, SPI, I2C, UART
Maximum Clock Frequency
100 MHz
Number Of Programmable I/os
2
Number Of Timers
2
Operating Supply Voltage
1.71 V to 3.6 V
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Package / Case
LQFP-100
Operating Temperature Range
- 40 C to + 105 C
Processor To Be Evaluated
MK60DX256ZVLL10
Supply Current (max)
185 mA
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MK60DX256ZVLL10
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
3.6 Relationship between ratings and operating requirements
–∞
3.7 Guidelines for ratings and operating requirements
Follow these guidelines for ratings and operating requirements:
3.8 Definition: Typical value
A typical value is a specified value for a technical characteristic that:
Typical values are provided as design guidelines and are neither tested nor guaranteed.
3.8.1 Example 1
This is an example of an operating behavior that includes a typical value:
Freescale Semiconductor, Inc.
- Probable permanent failure
• Never exceed any of the chip’s ratings.
• During normal operation, don’t exceed any of the chip’s operating requirements.
• If you must exceed an operating requirement at times other than during normal
• Lies within the range of values specified by the operating behavior
• Given the typical manufacturing process, is representative of that characteristic
operation (for example, during power sequencing), limit the duration as much as
possible.
during operation when you meet the typical-value conditions or other specified
conditions
range
Fatal
- No permanent failure
- Possible decreased life
- Possible incorrect operation
K60 Sub-Family Data Sheet Data Sheet, Rev. 5, 5/2011.
operating
Limited
range
- No permanent failure
- Correct operation
- No permanent failure
Preliminary
Handling range
operating
Normal
range
- No permanent failure
- Possible decreased life
- Possible incorrect operation
operating
Limited
range
Terminology and guidelines
- Probable permanent failure
range
Fatal
9