AD9898KCP-20 Analog Devices Inc, AD9898KCP-20 Datasheet - Page 42

IC CCD SIGNAL PROC/GEN 48-LFCSP

AD9898KCP-20

Manufacturer Part Number
AD9898KCP-20
Description
IC CCD SIGNAL PROC/GEN 48-LFCSP
Manufacturer
Analog Devices Inc
Type
CCD Signal Processor, 10-Bitr
Datasheet

Specifications of AD9898KCP-20

Rohs Status
RoHS non-compliant
Input Type
Logic
Output Type
Logic
Interface
3-Wire Serial
Mounting Type
Surface Mount
Package / Case
48-LFCSP
Analog Front End Type
CCD
Analog Front End Category
Video
Interface Type
Serial (3-Wire)
Input Voltage Range
0.5V
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (typ)
3V
Operating Supply Voltage (max)
3.6V
Resolution
10b
Number Of Adc's
1
Power Supply Type
Analog/Digital
Operating Temp Range
-20C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
48
Package Type
LFCSP EP
Number Of Channels
3
Current - Supply
-
Lead Free Status / RoHS Status
Not Compliant
AD9898
MSHUT CONTROL
MSHUT Basic Operation
The AD9898 provides an MSHUT output pulse that can be
configured to control the mechanical shutter of the camera.
The registers used to control the MSHUT pulse are listed in
Table XXV.
The MSHUT pulse can be placed at the start of any line by using
the 11-bit MSHUTPOS register. The MSHUT pulsewidth is
controlled using the MSHUTLEN register.
Register Name
MSHUTPAT
MSHUTINIT
MSHUTEN
MSHUTPOS
MSHUTPOS_HP
MSHUTLEN
STROBE_EN
MSHUTPAT0
MSHUTPAT1
MSHUTPAT2
MSHUTPAT3
SUBCK
MSHUT
VSG1–
VSG2
Figure 45. Example of MSHUT Timing with MSHUTEN = 1 and MSHUTPOS_HP = 0
VD
HD
HD
Bit Width
2
1
1
11
3
8
1
Figure 44. MSHUT Patterns Available by Setting MSHUTPAT Register
MSHUTPOS = 3
1
2
Register Type
Control (Addr 0x01)
Control (Addr 0x0C)
Control (Addr 0x0C)
Control (Addr 0x0C)
Control (Addr 0x0C)
Sys_Reg(13)
Control (Addr 0x0B)
Table XXV. MSHUT and STROBE Registers
3
1
MSHUTPAT = 0, MSHUTLEN = 5
2
MSHUTLEN + 1
3
4
–42–
Description
Selects MSHUT Pattern (See Figure 44)
(0 = MSHUTPAT0, 1 = MSHUTPAT1, 2 = MSHUTPAT2,
3 = MSHUTPAT3)
MSHUT Initialize
(1 = MSHUT Output Held LOW, 0 = Normal Operation Resumes)
MSHUT Control (0 = MSHUT Held at Last State,
1 = MSHUT Output Enabled for Normal Operation)
MSHUT Position during Normal Operation
MSHUT Position during High Precision Operation
MSHUT Pattern Length (See Figures 44 and 45)
STROBE Output Enable Control
(0 = STROBE Output Held Low, 1 = Enable STROBE Output)
5
The AD9898 offers four preprogrammed MSHUT patterns that
are selectable using the MSHUTPAT register. The
preprogrammed length is the same for all patterns set by the
MSHUTLEN register, but the active ON period of the
MSHUT pulse is different for each pattern, as shown in Figure
44. Figure 45 shows an example of selecting MSHUTPAT0
positioned to start three lines after the falling edge of VD with
MSHUTLEN = 5.
t
EXP
6
REV. 0

Related parts for AD9898KCP-20