LM3S308 Luminary Micro, Inc, LM3S308 Datasheet - Page 348

no-image

LM3S308

Manufacturer Part Number
LM3S308
Description
Lm3s308 Arm Microcontroller
Manufacturer
Luminary Micro, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM3S308
Manufacturer:
DSP
Quantity:
648
Part Number:
LM3S308-EQN25-C2
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S308-EQN25-C2T
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S308-IGZ25-C2
Manufacturer:
AV
Quantity:
241
Company:
Part Number:
LM3S308-IGZ25-C2
Quantity:
982
Part Number:
LM3S308-IQN25
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S308-IQN25-C2
Manufacturer:
TI
Quantity:
202
Part Number:
LM3S308-IQN25-C2
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
LM3S308-IQN25-C2T
Manufacturer:
Texas Instruments
Quantity:
10 000
Reset
Reset
Type
Type
Inter-Integrated Circuit (I
Write-Only Control Register
I2C Master Control/Status (I2CMCS)
I2C Master 0 base: 0x4002.0000
Offset 0x004
Type WO, reset 0x0000.0000
348
Bit/Field
Bit/Field
31:4
WO
WO
3
2
1
0
3
2
31
15
0
0
WO
WO
30
14
0
0
WO
WO
ADRACK
29
13
DATACK
reserved
ERROR
0
0
Name
BUSY
Name
STOP
ACK
2
C) Interface
WO
WO
28
12
0
0
WO
WO
27
11
0
0
Type
Type
WO
WO
WO
RO
RO
RO
RO
WO
WO
26
10
0
0
reserved
WO
WO
Reset
Reset
25
0x00
0
9
0
0
0
0
0
0
0
Preliminary
WO
WO
24
0
8
0
reserved
Description
Acknowledge Data
This bit specifies the result of the last data operation. If set, the
transmitted data was not acknowledged; otherwise, the data was
acknowledged.
Acknowledge Address
This bit specifies the result of the last address operation. If set, the
transmitted address was not acknowledged; otherwise, the address was
acknowledged.
Error
This bit specifies the result of the last bus operation. If set, an error
occurred on the last operation; otherwise, no error was detected. The
error can be from the slave address not being acknowledged, the
transmit data not being acknowledged, or because the controller lost
arbitration.
I
This bit specifies the state of the controller. If set, the controller is busy;
otherwise, the controller is idle. When the BUSY bit is set, the other status
bits are not valid.
Description
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
Data Acknowledge Enable
When set, causes received data byte to be acknowledged automatically
by the master. See field decoding in Table 14-3 on page 349.
Generate STOP
When set, causes the generation of the STOP condition. See field
decoding in Table 14-3 on page 349.
2
C Busy
WO
WO
23
0
7
0
WO
WO
22
0
6
0
WO
WO
21
0
5
0
WO
WO
20
0
4
0
ACK
WO
WO
19
0
3
0
STOP
WO
WO
18
0
2
0
START
WO
WO
17
0
1
0
June 04, 2008
RUN
WO
WO
16
0
0
0

Related parts for LM3S308