FWIXEPAD0SE001 INTEL [Intel Corporation], FWIXEPAD0SE001 Datasheet - Page 145

no-image

FWIXEPAD0SE001

Manufacturer Part Number
FWIXEPAD0SE001
Description
Advanced 8-Port 10/100 Mbps PHY Transceivers
Manufacturer
INTEL [Intel Corporation]
Datasheet
4.9.3
Datasheet
Document Number: 249241
Revision Number: 007
Revision Date: August 28, 2003
Table 46. 4B/5B Coding
PMA Sublayer
The 100BASE-X PMA protocol uses the 4B/5B data encoding scheme to encode/decode the data
streams. The coding scheme is shown in
1. The /I/ (Idle) code group is sent continuously between frames.
2. The /J/ and /K/ (SSD) code groups are always sent in pairs; /K/ follows /J/.
3. The /T/ and /R/ (ESD) code groups are always sent in pairs; /R/ follows /T/.
4. An /H/ (Error) code group is used to signal an error condition.
Code Type
CONTROL
INVALID
DATA
IDLE
LXT9785 and LXT9785E Advanced 8-Port 10/100 Mbps PHY Transceivers
undefined
undefined
undefined
undefined
undefined
undefined
undefined
undefined
undefined
undefined
undefined
undefined
undefined
undefined
4B Code
3 2 1 0
0 0 0 0
0 0 0 1
0 0 1 0
0 0 1 1
0 1 0 0
0 1 0 1
0 1 1 0
0 1 1 1
1 0 0 0
1 0 0 1
1 0 1 0
1 0 1 1
1 1 0 0
1 1 0 1
1 1 1 0
1 1 1 1
0 1 0 1
0 1 0 1
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Name
K
T
R
H
J
I
A
B
C
D
E
0
1
2
3
4
5
6
7
8
9
F
1
2
2
3
3
4
Table
46.
5B Code
4 3 2 1 0
1 1 1 1 0
0 1 0 0 1
1 0 1 0 0
1 0 1 0 1
0 1 0 1 0
0 1 0 1 1
0 1 1 1 0
0 1 1 1 1
1 0 0 1 0
1 0 0 1 1
1 0 1 1 0
1 0 1 1 1
1 1 0 1 0
1 1 0 1 1
1 1 1 0 0
1 1 1 0 1
1 1 0 0 0
1 0 0 0 1
0 1 1 0 1
0 0 1 1 1
0 0 1 0 0
0 0 0 0 0
0 0 0 0 1
0 0 0 1 0
0 0 0 1 1
0 0 1 0 1
0 0 1 1 0
0 1 0 0 0
0 1 1 0 0
1 0 0 0 0
1 1 0 0 1
1 1 1 11
Data 0
Data 1
Data 2
Data 3
Data 4
Data 5
Data 6
Data 7
Data 8
Data 9
Data A
Data B
Data C
Data D
Data E
Data F
Idle. Used as inter stream fill code.
Start-of-Stream Delimiter (SSD),
part 1 of 2.
Start-of-Stream Delimiter (SSD),
part 2 of 2.
End-of-Stream Delimiter (ESD),
part 1 of 2.
End-of-Stream Delimiter (ESD),
part 2 of 2.
Transmit Error. Used to force
signaling errors.
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Invalid
Interpretation
147