E6CP-AG5C-C Omron, E6CP-AG5C-C Datasheet
E6CP-AG5C-C
Specifications of E6CP-AG5C-C
Related parts for E6CP-AG5C-C
E6CP-AG5C-C Summary of contents
Page 1
... Cam Positioner H8PS Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and Application Considerations (page 32), and Safety Precautions (pages 17 and 18). This Compact Cam Positioner, Popular for It’s Ease-of-use, Now Comes with Even Better Functions. • ...
Page 2
... Yes PNP transistor output NPN transistor output PNP transistor output NPN transistor output PNP transistor output NPN transistor output PNP transistor output Model E6CP-AG5C-C 256 2M E6C3-AG5C-C 256 1M E6C3-AG5C-C 256 2M E6C3-AG5C-C 360 2M E6C3-AG5C-C 720 2M E6F-AG5C-C 256 2M E6F-AG5C-C 360 2M E6F-AG5C-C 720 2M Specification Model ...
Page 3
Specifications ■ Ratings Item Rated supply voltage 24 VDC Operating voltage range 85% to 110% of rated supply voltage Mounting method Flush mounting Power consumption Approx. 4 26.4 VDC for 8-output models Approx. 6 26.4 VDC ...
Page 4
... Note: 1. Cam output precision, however max. for Encoder with 256 resolution (P/R). 2. Although 32-output Models can have 10 steps set for any one output, there must be no more than 160 steps total set for all cam outputs. 3. The maximum is 1000 r/min when an E6CP-AG5C-C Encoder is connected. 4. ADV stands for Advance Angle Compensation. ...
Page 5
Functions Item Encoder rotation direction Encoder data can be set with a DIP switch to forward (CW) or reverse (CCW) direction. switching Encoder origin designation The present display angular position can be set to 0 (origin) by pressing the ...
Page 6
Connections ■ Terminal Arrangement H8PS-8@ (8-output Models) NPN Output, Encoder Flush Mounting H8PS-8@ Alignment markings (Rear view NPN Output, Encoder Surface Mounting H8PS-8@F Alignment markings 9 10 ...
Page 7
... E5ZE-CBL200 Connector-type Output Cable (Order Separately) Connections H8PS-16@/-32@ E5ZE-CBL200 Connector-type Output Cable (Order Separately) (CN1) (CN2) Output Output Cable 1 Cable 2 XG4M-2030 MIL Connector (made by OMRON) Output Cable 1 Wiring Table Outputs Connector Outputs Connector pin No. pin No. Cam 1 20 Cam 9 19 Cam 2 18 ...
Page 8
Y92S-41-200 Discrete Wire Output Cable (Order Separately) Connections H8PS-16@/-32@ Y92S-41-200 Discrete Wire Output Cable (Order Separately) (CN1) (CN2) Output Cable 1 Output Cable 2 H8PS 8 Cam Positioner Output Cable 1 Wiring Table Outputs Cable Marks Marking color color ...
Page 9
Input Connections Only the Encoder inputs are connected with 8-output Models. The inputs are no-voltage (short-circuit or open) inputs. No-voltage Inputs Open Collector PLC, sensor, etc. H8PS-16 H8PS-32@ Note: Operates when the transistor ...
Page 10
Operating Mode ■ Functions The H8PS Cam Positioner receives angle signal inputs from the Dedicated Absolute Encoder and outputs the preset ON/OFF angles as cam outputs. Program Examples 1. H8PS-8@ (8-output Models) Cam output Step 0 (cam number) ON angle ...
Page 11
Nomenclature ■ Displays 8-output Models (1) Cam output indicators (2) PV/SV indicator (4) Rotation display monitor CAM STEP (6) Cam No. display (7) Step No. display 16-/32-output Models (1) Cam output indicators (2) ...
Page 12
Dimensions Note: All units are in millimeters unless otherwise indicated. ■ Main Unit Cam Positioners Flush Mounting Models H8PS-8B@ (8-output Models) H8PS-16B@ (16-output Models) H8PS-32B@ (32-output Models) Surface Mounting Models H8PS-8BF@ (8-output Models) H8PS-16BF@ (16-output Models) H8PS-32BF@ (32-output Models) H8PS ...
Page 13
Encoder Connecting Direction H8PS-8B@ H8PS-8BF@ Encoder ■ Accessories (Order Separately) Parallel Input Adapters Y92C-30 This Adapter enables two H8PS Cam Positioners to share signals from an Encoder. Connected to the H8PS. Y92C-30 From the Dedicated Absolute Encoder Use the cable ...
Page 14
Accessories (Order Separately) Watertight Cover Y92A-96N Use for flush mounting when waterproofing is required. The Y96A-96N conforms to IP66 and NEMA4 (for indoor use) standards for waterproofing. The operating environment may cause the waterproof packing to deteriorate, shrink, or ...
Page 15
... Weight Approx. 200 g (with 2-m cord) Datasheet Cat. No. --- Note: 1. The following inrush currents flow when the power is turned ON. E6CP-AG5C-C: Approx (time: approx. 0.3 ms), E6C3-AG5C-C: Approx (time: approx. 0.8 ms), E6F-AG5C-C: Approx (time: approx JEM1030: Applicable as of 1991 E6C3-AG5C-C 256 (8-bit), 360 (9-bit), or 720 (10-bit) Applied voltage: 30 VDC max ...
Page 16
... Dimensions Note: All units are in millimeters unless otherwise indicated. E6CP-AG5C-C Note: Order the E69-C06B Coupling separately. Accessory Mounting Bracket (Included) 2 5.5 dia. holes (18 +0.1 8 3.1 0 Two (5.1) E6C3-AG5C-C D cut: Phase-Z position (range 0.1 dia. Three, M4 holes (depth: 5) Note: Order the E69-C08B Coupling separately ...
Page 17
... Note 1: E6F-AG5C-C, E6CP-AG5C-C, and E6C3-AG5C-C Connectors for the H8PS. Note 2: 6-dia., 12-core shielded cord (cross-sectional area: 0.2 mm Note 3: Connected to the H8PS Cam Positioner. Mounting Procedure 1 Insert the shaft into the Coupling. ...
Page 18
Safety Precautions (Cam Positioner) !CAUTION Tighten terminal screws to a torque of 0.80 N·m so that they do not become loose. Minor fires or malfunction may occasionally occur. For 16- and 32-output Models, leave the protective label attached to the ...
Page 19
Precautions for Correct Use • A cam output will remain ON if the set angles for two steps overlap for the same cam number. Step 1: 120 ON 170 OFF Step 2: 150 ON 210 OFF ON OFF 120 ...
Page 20
Operating Procedures ■ Flow of Operation Initial Settings Setting Resolution and The Encoder resolution and rotation direction is set on a DIP switch. Rotation Direction ➾ For details on the setting methods, refer to page 21. The Encoder is mounted ...
Page 21
Setting Resolution and Rotation Direction One of three resolutions can be selected for the Encoder connected to the H8PS: 256, 360, or 720. The resolution and display angle are set here. Turn OFF the power supply. Set the display angle ...
Page 22
Setting ON/OFF Angles in Manual Mode ON/OFF angles can be set manually using the ANGLE Keys on the front of the Cam Positioner. Example: Setting Step 1 of Cam No Turn and Turn OFF at ...
Page 23
Setting ON/OFF Angles Using Support Software With 16-/32-output models, programs can be uploaded or downloaded easily with the optional Support Software (H8PS-SOFT- V1) by connecting a personal computer to the Cam Positioner using the optional Y92S-40 USB cable. Support Software ...
Page 24
Operation (Run Mode) Starting Operation Set the mode switch to RUN to start operation. Mode PRGM TEST RUN RUN Start input indication (See note.) STEP CAM Note: For 16/32-output models, be sure that the start input is ...
Page 25
Clearing Settings Clearing All Programs The all clear function can be used to delete all cam programs, the settings for advance angle compensation function, and all other settings. All settings in the Function Setting Mode will be returned to their ...
Page 26
Advanced Functions Set the advanced functions as required to perform more advanced operation. Outlines of the advanced functions are provided on the following pages. For details, refer to the Operation Manual (Cat. No. Z199). Mode Transitions PRGM TEST PRG ...
Page 27
Advance Angle Compensation (ADV) Function The advance angle compensation function automatically advances the ON/OFF angle of cam outputs in proportion to machine (encoder) speed. As the speed of the machine increases, the system can be affected by the delay in ...
Page 28
Pulse Output (f1/f2) Outputs a preset number of pulses per Encoder rotation. Pulses are output at a 1:1 ON/OFF ratio and pulse output can be started from a specified angle. Operation for 9 Output Pulses and a Start Angle of ...
Page 29
Step Number Limit (f5) With the H8PS steps can be set to turn the output ON/OFF 10 times for each cam. The number of steps that can be set, however, can be restricted to prevent programming from ...
Page 30
Bank Switching Method (f8) The following methods can be used to switch the bank: the bank inputs on the terminal block or the BANK Key on the front of the Cam Positioner. The method is set using the F8 menu ...
Page 31
Self Diagnostic Function The following displays will appear on the main display if an error occurs error occurs, all outputs (including cam, pulse, and run outputs) will be turned OFF. Display Meaning e00 Origin designation data error ...
Page 32
... OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE ...