E6CP-AG5C-C Omron, E6CP-AG5C-C Datasheet - Page 26

ENCODER ROTARY 12-24V 8-BIT RES

E6CP-AG5C-C

Manufacturer Part Number
E6CP-AG5C-C
Description
ENCODER ROTARY 12-24V 8-BIT RES
Manufacturer
Omron
Series
E6CPr

Specifications of E6CP-AG5C-C

Encoder Type
Optical
Output Type
Gray Code (Absolute)
Pulses Per Revolution
256
Voltage - Supply
12 ~ 24VDC
Actuator Type
6mm Dia Flatted End
Detent
No
Built In Switch
No
Mounting Type
Chassis Mount
Orientation
Right Angle
Termination Style
Cable with Connector
Svhc
No SVHC (15-Dec-2010)
Encoder Resolution
256
Operating Temperature Range
-10°C To +55°C
Rotational Speed
1000rpm
External Depth
53mm
External Length / Height
96mm
External Width
96mm
Supply Voltage Range
12V To 24V
Sensor Supply Voltage
12V To 24V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rotational Life (cycles Min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E6CPAG5CC
■ Advanced Functions
Set the advanced functions as required to perform more advanced operation. Outlines of the advanced functions are provided on the following
pages. For details, refer to the Operation Manual (Cat. No. Z199).
Mode Transitions
26
Disables all keys
and switches.
will light when the all
protection function is
enabled.
ADV Key 5 s min.
All Protection
PRGM
PRGM
PRGM
TEST
TEST
TEST
RUN
RUN
RUN
Refer to page 24.
Cam Positioner
Programming Mode
Test Mode
Run Mode
Changed with the mode switch.
Changed with the mode switch.
H8PS
Main Display: Angle
Sub-display: Speed
Main Display: Speed
Sub-display: Angle
Switching the Angle
and Speed Display
Refer to page 24.
RUN
PRG
TST
ON/OFF Key 1 s min.
ADV Key 3 s min.
Advance angle
compensation (ADV)
function automatically
advances the ON/OFF
angle of outputs in
proportion to the
machine (Encoder)
speed.
Setting the
ADV Function
ADV Key
The values in parentheses are the default settings.
Note 1: The default setting is for 10 steps for all cams.
Note 2: Not displayed when F7 is disabled.
Shaded items above are not displayed for 8-output models.
: No. of pulse outputs [60]
: Pulse output start angle [0 ]
: Speed alarm upper limit [---]
: Speed alarm lower limit [---]
: Step number limit [---] (See note 1.)
: Cam protection [None]
: Bank enable/disable [Disable]
: Bank switching method [Bank inputs] (See note 2.)
: Bank copy (See note 2.)
: E24 detection enable/disable [Enable]
Function Setting Mode
ADV Key
ADV Key
ADV Key
ADV Key
ADV Key
ADV Key
ADV Key
ADV Key
ADV Key
ADV Key
Refer to pages 28 to 30.

Related parts for E6CP-AG5C-C