E6CP-AG5C-C Omron, E6CP-AG5C-C Datasheet - Page 18

ENCODER ROTARY 12-24V 8-BIT RES

E6CP-AG5C-C

Manufacturer Part Number
E6CP-AG5C-C
Description
ENCODER ROTARY 12-24V 8-BIT RES
Manufacturer
Omron
Series
E6CPr

Specifications of E6CP-AG5C-C

Encoder Type
Optical
Output Type
Gray Code (Absolute)
Pulses Per Revolution
256
Voltage - Supply
12 ~ 24VDC
Actuator Type
6mm Dia Flatted End
Detent
No
Built In Switch
No
Mounting Type
Chassis Mount
Orientation
Right Angle
Termination Style
Cable with Connector
Svhc
No SVHC (15-Dec-2010)
Encoder Resolution
256
Operating Temperature Range
-10°C To +55°C
Rotational Speed
1000rpm
External Depth
53mm
External Length / Height
96mm
External Width
96mm
Supply Voltage Range
12V To 24V
Sensor Supply Voltage
12V To 24V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rotational Life (cycles Min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E6CPAG5CC
Safety Precautions (Cam Positioner)
18
Tighten terminal screws to a torque of 0.80 N·m so that
they do not become loose.
Minor fires or malfunction may occasionally occur.
For 16- and 32-output Models, leave the protective label
attached to the H8PS when wiring. Removing the label
before wiring may occasionally result in fire if foreign
matter enters the Unit.
Remove the label after the completion of wiring to ensure
proper heat dissipation. Leaving the label attached may
occasionally result in fire.
Do not disassemble, modify, or repair the H8PS or touch
any of the internal parts. Otherwise, minor electric shock,
fire, or malfunction may occasionally occur.
Do no allow metal fragments, lead wire scraps, or chips
from processing during installation to fall inside the H8PS.
Otherwise, minor electric shock, fire, or malfunction may
occasionally occur.
Do not touch the terminals when power is being supplied.
For Surface-mounting H8PS, always connect the terminal
cover for after completing wiring. Otherwise, minor injury
due to electric shock may occasionally occur.
Cam Positioner
!CAUTION
H8PS
■ Precautions for Safe Use
Observe the following items to ensure the safe use of this product.
Environmental Precautions
• Store the H8PS within specified ratings. If the H8PS has been
• Use the H8PS within the specified ratings for operating temperature
• Do not operate the H8PS in locations subject to sudden or extreme
• Do not use the H8PS in locations subject to vibrations or shock.
• Do not use the H8PS in locations subject to excessive dust,
• Install the H8PS well away from any sources of static electricity,
• The H8PS is not waterproof or oil resistant.
• The life expectancy of internal components may be reduced if the
• Do not use organic solvents (such as paint thinner or benzine),
Usage Precautions
• Install a switch or circuit breaker that allows the operator to
• Pay careful attention to polarity to avoid wrong connections when
• Do not connect more than two crimp terminals to the same
• Use the specified wires for wiring.
• Do not connect loads that exceed the rated output current. The
• Always connect a diode to protect against counterelectromotive
• Use the specified cables to connect outputs.
• Do not install input lines in the same duct or conduit as power
• Internal elements may be destroyed if a voltage outside the rated
• Maintain voltage fluctuations in the power supply within the
• Use a switch, relay, or other contact so that the rated power supply
• Do not turn OFF the power supply when changing or deleting
stored at temperatures 10 C or lower, let it stand for 3 hours or
longer at room temperature before turning ON the power supply.
and humidity.
changes in temperature, or locations where high humidity may
result in condensation.
Extended use in such locations may result in damage due to stress.
corrosive gas, or direct sunlight.
such as pipes transporting molding materials, powders, or liquids.
Do not use it in locations subject to water or oil.
H8PS is mounted side-by-side.
strong alkaline, or strong acids because they will damage the
external finish.
immediately turn OFF the power, and label it to clearly indicate its
function.
wiring terminals.
terminal.
Applicable Wires
output elements may be destroyed, possibly resulting in short-
circuit or open-circuit faults.
force when using an inductive load. Counterelectromotive force
may destroy output elements, possibly resulting in short-circuit or
open-circuit faults.
supply or other high-voltage lines. Doing so may result in
malfunction due to noise. Separate the input lines from high-
voltage lines.
voltage is applied.
specified range.
voltage will be reached within 0.1 s. If the power supply voltage is
not reached quickly enough, the H8PS may malfunction or outputs
may be unstable.
settings. The contents of the EEPROM may be corrupted.
AWG24 to AWG18 (cross-sectional area of 0.208 to 0.832 mm
Solid or twisted wires of copper
2
)

Related parts for E6CP-AG5C-C