E6CP-AG5C-C Omron, E6CP-AG5C-C Datasheet - Page 24

ENCODER ROTARY 12-24V 8-BIT RES

E6CP-AG5C-C

Manufacturer Part Number
E6CP-AG5C-C
Description
ENCODER ROTARY 12-24V 8-BIT RES
Manufacturer
Omron
Series
E6CPr

Specifications of E6CP-AG5C-C

Encoder Type
Optical
Output Type
Gray Code (Absolute)
Pulses Per Revolution
256
Voltage - Supply
12 ~ 24VDC
Actuator Type
6mm Dia Flatted End
Detent
No
Built In Switch
No
Mounting Type
Chassis Mount
Orientation
Right Angle
Termination Style
Cable with Connector
Svhc
No SVHC (15-Dec-2010)
Encoder Resolution
256
Operating Temperature Range
-10°C To +55°C
Rotational Speed
1000rpm
External Depth
53mm
External Length / Height
96mm
External Width
96mm
Supply Voltage Range
12V To 24V
Sensor Supply Voltage
12V To 24V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rotational Life (cycles Min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E6CPAG5CC
Operation (Run Mode)
Starting Operation
Switching the Angle and Speed Displays
24
Start input
indication
(See note.)
Press the
the display positions of the present angular position and speed (r/min)
between main display and sub-display.
Set the mode switch to RUN to start operation.
1
1
2
2
CAM
ON
Note: For 16/32-output models, be sure that the start input is
1
Cam Positioner
2
OFF
7
7
PRGM
ON and that the start input indicator is lit. Outputs
(including the cam, pulse, and run outputs) will not
function if the start input is OFF. The 8-output models do
not have a start input.
TEST
RUN
Press the
Mode
Key for at least 1 s in Run Mode to reverse
STEP
7
ON
RUN
RUN
OFF
Key for 1 s min.
H8PS
Present angular position on main display
Speed (r/min) on sub-display
Speed (r/min) on main display
Present angular position on sub-display
RUN
Present angular position
Speed (r/min)
All Protection Function
The all protection function locks the H8PS in Run Mode and prohibits
any changes to settings. It can be used to prevent incorrect or
unauthorized operation. If the
Run Mode, the All Protection indicator
and all keys and switches will be disabled. If the mode switch is
changed to Programming or Test Mode while protection is enabled,
the All Protection indicator
cannot be changed. If a setting on the DIP switch is changed while
protection is enabled, the All Protection indicator
the power supply is turned ON to indicate that settings cannot be
changed.
Checking ON/OFF Angle Settings
• During Run Mode, the CAM Keys
All Protection Function Disabled (Normal Operation)
All Protection Function Enabled
CAM
CAM
can be used to check the ON/OFF angle settings for any step. Also,
the
settings in order for all steps starting from cam 1. If there is no key
operation for 10 s or longer during the checking operation, the
previous display will be resumed.
1
1
2
2
CHECK
4
4
5
5
STEP
STEP
6
6
Key can be pressed to check the ON/OFF angle
Press the
ADV
RUN
RUN
Key for 5 s min.
ADV
will flash to indicate that settings
All protection indication
Key is pressed for at least 5 s in
and STEP Keys
will light on the display
will flash when