E6CP-AG5C-C Omron, E6CP-AG5C-C Datasheet - Page 5

ENCODER ROTARY 12-24V 8-BIT RES

E6CP-AG5C-C

Manufacturer Part Number
E6CP-AG5C-C
Description
ENCODER ROTARY 12-24V 8-BIT RES
Manufacturer
Omron
Series
E6CPr

Specifications of E6CP-AG5C-C

Encoder Type
Optical
Output Type
Gray Code (Absolute)
Pulses Per Revolution
256
Voltage - Supply
12 ~ 24VDC
Actuator Type
6mm Dia Flatted End
Detent
No
Built In Switch
No
Mounting Type
Chassis Mount
Orientation
Right Angle
Termination Style
Cable with Connector
Svhc
No SVHC (15-Dec-2010)
Encoder Resolution
256
Operating Temperature Range
-10°C To +55°C
Rotational Speed
1000rpm
External Depth
53mm
External Length / Height
96mm
External Width
96mm
Supply Voltage Range
12V To 24V
Sensor Supply Voltage
12V To 24V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rotational Life (cycles Min)
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
E6CPAG5CC
■ Functions
Encoder rotation direction
switching
Encoder origin designation
Angle display switch
Rotation display monitor
Teaching function
Pulse output
Switching the angle and
speed displays
Bank function
Advance angle compensation
(ADV) function
Speed alarm output
All protection function
Cam protection function
Step number limit
Output prohibit
Support Software settings
Item
Encoder data can be set with a DIP switch to forward (CW) or reverse (CCW) direction.
The present display angular
position can be set to 0 (origin) by
pressing the ORIGIN Key on the
front panel.
Converts the Absolute Encoder value display from 256 divisions/revolution to 360 /revolution.
Graphically displays the Encoder rotational angular position.
Sets the cam output ON/OFF angle based on actual machine (Encoder) operation.
Outputs a preset number of pulses per Encoder rotation. It also sets the pulse output start angle.
Displays both the present angular position and the number of Encoder revolutions (speed) in Run Mode.
Switches back and forth between the main display showing the present angular position with the sub-display
showing the speed and the main display showing the speed with the sub-display showing the present angular
position.
---
Automatically advances the ON/OFF angle of cam outputs in proportion to machine (encoder) speed to
compensate for the delay in timing of ON/OFF operation. ADV values can be set individually for 7 cam outputs.
A specified cam output can be used as an Encoder speed alarm output.
The function can output upper and lower limit speed alarms.
Disables all key and switch operations in Run Mode to prevent incorrect or unauthorized operation.
Prohibits program changes at the cam output level. Any cam numbers can be protected.
Limits the number of steps that can be set per cam output. Prohibits incorrect operations by adding to the
program.
---
---
H8PS-8@
The present display angular position can be set to 0 (origin) by using the
origin input terminal or the ORIGIN Key on the front panel.
Note: All banks use the same origin.
banks (0 to 7).
The bank that is running can be switched using the bank input terminal or the
BANK Key on the front panel.
Also enables programs to be copied between banks.
output.
Note: Use this function carefully for the application because no cam outputs
computer to the Cam Positioner using a USB Cable (Y92S-40, sold
separately) and the Support Software (H8PS-SOFT-V1, sold separately).
Enables the entire cam program to be changed at one time by switching
The start input can be turned OFF in Run or Test Mode to prohibit cam
Programs can be uploaded or downloaded easily by connecting a personal
are provided when the start input is turned OFF.
H8PS-16@
Cam Positioner
H8PS
H8PS-32@
5