EP9301-IQZ Cirrus Logic Inc, EP9301-IQZ Datasheet - Page 544

32-Bit Microcontroller IC

EP9301-IQZ

Manufacturer Part Number
EP9301-IQZ
Description
32-Bit Microcontroller IC
Manufacturer
Cirrus Logic Inc
Series
EP9r
Datasheets

Specifications of EP9301-IQZ

Controller Family/series
(ARM9)
Core Size
32 Bit
A/d Converter
12 Bits
Supply Voltage
3.3V
No. Of I/o Pins
24
Mounting Type
Surface Mount
Operating Temperature Min
-40°C
Package / Case
208-LQFP
Core Processor
ARM9
Speed
166MHz
Connectivity
EBI/EMI, Ethernet, I²C, IrDA, SPI, UART/USART, USB
Peripherals
AC'97, DMA, I&sup2:S, LED, MaverickKey, POR, PWM, WDT
Number Of I /o
19
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 3.6 V
Data Converters
A/D 5x12b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Processor Series
EP93xx
Core
ARM920T
Data Bus Width
32 bit
Mounting Style
SMD/SMT
3rd Party Development Tools
MDK-ARM, RL-ARM, ULINK2
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-
Lead Free Status / Rohs Status
 Details
Other names
598-1250

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP9301-IQZ
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
14
UART1Ctrl
UART1Flag
14-22
UART1 With HDLC and Modem Control Signals
EP93xx User’s Guide
31
15
31
15
Address:
Default:
Definition:
Bit Descriptions:
30
14
30
14
29
13
29
13
28
12
28
12
0x808C_0014 - Read/Write
0x0000_0000
UART1 Control Register
RSVD:
LBE:
RTIE:
TIE:
RIE:
MSIE:
UARTE:
RSVD
RSVD
27
27
11
11
26
10
26
10
Copyright 2007 Cirrus Logic
25
25
9
9
Reserved. Unknown During Read.
Loopback Enable. If this bit is set to 1, data sent to TXD is
received on RXD. This bit is cleared to 0 on reset, which
disables the loopback mode.
Receive Timeout Enable. If this bit is set to 1, the receive
timeout interrupt is enabled.
Transmit Interrupt Enable. If this bit is set to 1, the transmit
interrupt is enabled.
Receive Interrupt Enable. If this bit is set to 1, the receive
interrupt is enabled.
Modem Status Interrupt Enable. If this bit is set to 1, the
modem status interrupt is enabled.
UART Enable. If this bit is set to 1, the UART is enabled.
Data transmission and reception occurs for UART signals.
24
24
8
8
RSVD
RSVD
TXFE
LBE
23
23
7
7
RXFF
RTIE
22
22
6
6
TXFF
TIE
21
21
5
5
RXFE
RIE
20
20
4
4
BUSY
MSIE
19
19
3
3
DCD
18
18
2
2
RSVD
DSR
17
17
1
1
DS785UM1
UARTE
CTS
16
16
0
0

Related parts for EP9301-IQZ