EP4CE40F29C8N Altera, EP4CE40F29C8N Datasheet - Page 357

no-image

EP4CE40F29C8N

Manufacturer Part Number
EP4CE40F29C8N
Description
IC CYCLONE IV FPGA 40K 780FBGA
Manufacturer
Altera
Series
CYCLONE® IV Er

Specifications of EP4CE40F29C8N

Number Of Logic Elements/cells
39600
Number Of Labs/clbs
2475
Total Ram Bits
1134000
Number Of I /o
532
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
780-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4CE40F29C8N
Manufacturer:
ALTERA43
Quantity:
1 602
Part Number:
EP4CE40F29C8N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CE40F29C8N
Manufacturer:
ALTERA
0
Part Number:
EP4CE40F29C8N
Manufacturer:
ALTERA
0
Part Number:
EP4CE40F29C8N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP4CE40F29C8N
0
Company:
Part Number:
EP4CE40F29C8N
Quantity:
2 800
Part Number:
EP4CE40F29C8N ALTERA
Manufacturer:
ALTERA
0
Chapter 1: Cyclone IV Transceivers Architecture
Self Test Modes
PRBS
Figure 1–74. PRBS Pattern Test Mode Datapath
Note to
(1) Serial loopback path is optional and can be enabled for the PRBS verifier to check the PRBS pattern
© December 2010 Altera Corporation
Fabric
FPGA
Figure
1–74:
Transmitter Channel PCS
Receiver Channel PCS
Transceiver
Compensation
Tx Phase
Compensation
The incremental pattern generator and verifier are 16-bits wide. The generated pattern
increments from 00 to FF and passes through the TX PCS blocks, parallel looped back
to RX PCS blocks, and checked by the verifier. The pattern is also available as serial
data at the tx_dataout port. The differential output voltage of the transmitted serial
data on the tx_dataout port is based on the selected V
data pattern is not available to the FPGA logic at the receiver for verification.
The following are the transceiver channel configuration settings in this mode:
The rx_bisterr and rx_bistdone signals indicate the status of the verifier. The
rx_bisterr signal is asserted and stays high when detecting an error in the data.
The rx_bistdone signal is asserted and stays high when the verifier either receives a
full cycle of incremental pattern or it detects an error in the receiver data. You can
reset the incremental pattern generator and verifier by asserting the
tx_digitalreset and rx_digitalreset ports, respectively.
Figure 1–74
modes. The pattern generator is located in TX PCS before the serializer, and PRBS
pattern verifier located in RX PCS after the word aligner.
FIFO
FIFO
Rx
PCS-FPGA fabric channel width: 16-bit
8B/10B blocks: Enabled
Byte serializer/deserializer: Enabled
Word aligner: Automatic synchronization state machine mode
Byte ordering: Enabled
Serializer
shows the datapath for the PRBS, high and low frequency pattern test
Ordering
Byte
Byte
Deserializer
Byte
PRBS, High Freq,
Low Freq Pattern
Encoder
8B/10B
Generator
Decoder
8B/10B
Match
FIFO
Rate
Verifier
PRBS
Aligner
Word
OD
Cyclone IV Device Handbook, Volume 2
settings. The incremental
serializer
Transmitter Channel PMA
Serializer
Receiver Channel
PMA
De-
Receiver
CDR
(1)
1–77