MC68SEC000AA16 Freescale Semiconductor, MC68SEC000AA16 Datasheet - Page 50

IC MPU 32BIT 16MHZ 64-QFP

MC68SEC000AA16

Manufacturer Part Number
MC68SEC000AA16
Description
IC MPU 32BIT 16MHZ 64-QFP
Manufacturer
Freescale Semiconductor
Series
M68000r
Datasheets

Specifications of MC68SEC000AA16

Processor Type
M680x0 32-Bit
Speed
16MHz
Voltage
3.3V, 5V
Mounting Type
Surface Mount
Package / Case
64-QFP
Processor Series
M680xx
Core
CPU32
Maximum Clock Frequency
16 MHz
Operating Supply Voltage
3.3 V, 5 V
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
0 C
Core Size
32 Bit
Cpu Speed
16MHz
Digital Ic Case Style
QFP
No. Of Pins
64
Supply Voltage Range
5V
Operating Temperature Range
0°C To +70°C
Frequency Typ
20MHz
Filter Terminals
SMD
Rohs Compliant
Yes
Clock Frequency
16MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68SEC000AA16
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68SEC000AA16
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MC68SEC000AA16R2
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Operating Modes and On-Chip Memory
MBE — Multiple-Byte Programming Enable Bit
Bit 6 — Unimplemented
ELAT — EPROM/OTPROM Latch Control Bit
EXCOL — Select Extra Columns Bit
EXROW — Select Extra Rows Bit
T[1:0] — EPROM Test Mode Select Bits
50
When multiple-byte programming is enabled, address bit 5 is considered a don’t care so that bytes with
address bit 5 = 0 and address bit 5 = 1 both get programmed. MBE can be read in any mode and
always reads 0 in normal modes. MBE can be written only in special modes.
Always reads 0
When ELAT = 1, writes to EPROM cause address and data to be latched and the EPROM/OTPROM
cannot be read. ELAT can be read any time. ELAT can be written any time except when PGM = 1; then
the write to ELAT is disabled.
These bits allow selection of either gate stress or drain stress test modes. They can be read and written
only in special modes and always read 0 in normal modes.
0 = EPROM array configured for normal programming
1 = Program two bytes with the same data
0 = EPROM/OTPROM address and data bus configured for normal reads
1 = EPROM/OTPROM address and data bus configured for programming
0 = User array selected
1 = User array is disabled and extra columns are accessed at bits [7:0]. Addresses use bits [13:5]
0 = User array selected
1 = User array is disabled and two extra rows are available. Addresses use bits [7:0] and bits [13:8]
and bits [4:0] are don’t care. EXCOL can be read and written only in special modes and always
returns 0 in normal modes.
are don’t care. EXROW can be read and written only in special modes and always returns 0 in
normal modes.
Address: $1036
Reset:
Read:
Write:
MBE
Bit 7
Figure 2-15. MC68HC711E20 EPROM Programming
0
= Unimplemented
6
0
T1
M68HC11E Family Data Sheet, Rev. 5.1
0
0
1
1
Control Register (EPROG)
ELAT
5
0
T0
0
1
0
1
EXCOL
4
0
Function Selected
Normal mode
Drain stress
Gate stress
Reserved
EXROW
3
0
T1
2
0
T0
1
0
Freescale Semiconductor
PGM
Bit 0
0

Related parts for MC68SEC000AA16