38.7.26
Name:
Address:
Access:
This register can only be written if the bits WPSWS5 and WPHWS5 are cleared in
page
• FPVHx: Fault Protection Value for PWMH output on channel x
0 = PWMH output of channel x is forced to 0 when fault occurs.
1 = PWMH output of channel x is forced to 1 when fault occurs.
• FPVLx: Fault Protection Value for PWML output on channel x
0 = PWML output of channel x is forced to 0 when fault occurs.
1 = PWML output of channel x is forced to 1 when fault occurs.
1044
1044
FPVH7
FPVL7
1051.
31
23
15
7
SAM3X/A
SAM3X/A
PWM Fault Protection Value Register
PWM_FPV
0x40094068
Read-write
FPVH6
FPVL6
30
22
14
6
FPVH5
FPVL5
29
21
13
5
FPVH4
FPVL4
28
20
12
4
FPVH3
FPVL3
27
19
11
3
FPVH2
FPVL2
“PWM Write Protect Status Register” on
26
18
10
2
FPVH1
FPVL1
25
17
9
1
11057A–ATARM–17-Feb-12
11057A–ATARM–17-Feb-12
FPVH0
FPVL0
24
16
8
0