TMPM364F10FG Toshiba, TMPM364F10FG Datasheet - Page 659

no-image

TMPM364F10FG

Manufacturer Part Number
TMPM364F10FG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMPM364F10FG

Product Summaries
Summary
Lead Free
Yes
Rohs Compatible Product(s)
Available
Rom (kbytes)
1024K
Rom Type
Flash
Ram (kbytes)
64K
Number Of Pins
144
Package
LQFP(20x20)
Vcc
3V
Cpu Mhz
64
Ssp (ch) Spi
1
I2c/sio (ch)
5
Uart/sio (ch)
12
Usb
Host
Can
1
Ethernet
-
External Bus Interface
Y
Cs/wait Controller (ch)
4
Dma Controller
2
10-bit Da Converter
-
10-bit Ad Converter
16
12-bit Ad Converter
-
16-bit Timer / Counter
16
Motor / Igbt Control
-
Real Time Clock
Y
Watchdog Timer
Y
Osc Freq Detect
-
Clock Gear
Y
Low-power Hold Function
Y
Remote Control Interface
Y
Hardware Cec Controller
Y
Comparators
-
Low-voltage Detector
-
Etm Hardware Trace
4-bit

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMPM364F10FG
Manufacturer:
Toshiba
Quantity:
10 000
Company:
Part Number:
TMPM364F10FG
Quantity:
6 000
1
0
Bit
PES
CCS
Bit Symbol
R/W
R/W
(HCD)
Type
R/W
R/W
Type
(HC)
(read)Port Enable Status
This bit indicates whether the port is enabled or disabled. The Root Hub may clear this bit when
an overcurrent condition, disconnect event, switched-off power, or operational bus error such as
babble is detected. This change also causes PortEnabledStatusChange to be set. HCD sets this
bit by writing SetPortEnable and clears it by writing ClearPortEnable. This bit cannot be set when
CurrentConnectStatus is cleared. This bit is also set, if not already, at the completion of a port re-
set when ResetStatusChange is set or port suspend when SuspendStatusChange is set.
0: Port is disabled.
1: Port is enabled.
(write)Set Port Enable
The HCD sets PortEnableStatus by writing a "1". Writing a "0" has no effect. If CurrentConnectSta-
tus is cleared, this write does not set PortEnableStatus, but instead sets ConnectStatusChange.
This informs the driver that it attempted to enable a disconnected port.
(read)Current Connect Status
This bit reflects the current state of the downstream port.
0: No device connected
1: Device connected
(write)Clear Port Enable
The HCD writes a "1" to this bit to clear the PortEnableStatus bit. Writing a "0" has no effect. The