DS2153QN-A7/T&R Maxim Integrated, DS2153QN-A7/T&R Datasheet - Page 26

no-image

DS2153QN-A7/T&R

Manufacturer Part Number
DS2153QN-A7/T&R
Description
Network Controller & Processor ICs
Manufacturer
Maxim Integrated
Datasheet

Specifications of DS2153QN-A7/T&R

Product
Framer
Number Of Transceivers
1
Supply Current (max)
65 mA
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
PLCC-44
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
5 V
Supply Voltage - Max
5.25 V
Supply Voltage - Min
4.8 V
Part # Aliases
90-2153Q-NT7
6 ERROR COUNT REGISTERS
There are a set of four counters in the DS2153Q that record bipolar or code violations, errors in the CRC4
SMF codewords, E bits as reported by the far end, and word errors in the FAS. Each of these four
counters are automatically updated on either 1-second boundaries (CCR2.7 = 0) or every 62.5ms
(CCR2.7 = 1) as determined by the timer in Status Register 2 (SR2.4). Hence, these registers contain
performance data from either the previous second or the previous 62.5ms. The user can use the interrupt
from the timer to determine when to read these registers. The user has a full second (or 62.5ms) to read
the counters before the data is lost.
6.1 BPV or Code Violation Counter
Violation Count Register 1 (VCR1) is the most significant word and VCR2 is the least significant word of
a 16-bit counter that records either Bipolar Violations (BPVs) or Code Violations (CVs). If CCR2.6 = 0,
then the VCR counts bipolar violations. Bipolar violations are defined as consecutive marks of the same
polarity. In this mode, if the HDB3 mode is set for the receive side via CCR1.2, then HDB3 codewords
are not counted as BPVs. If CCR2.6 = 1, then the VCR counts code violations as defined in CCITT
O.161. Code violations are defined as consecutive bipolar violations of the same polarity. In most
applications, the DS2153Q should be programmed to count BPVs when receiving AMI code and to count
CVs when receiving HDB3 code. This counter increments at all times and is not disabled by loss of sync
conditions. The counter saturates at 65,535 and will not rollover. The bit error rate on an E1 line would
have to be greater than 10**-2 before the VCR would saturate.
VCR1: UPPER BIPOLAR VIOLATION COUNT REGISTER 1 (Address = 00
Hex)
VCR2: LOWER BIPOLAR VIOLATION COUNT REGISTER 2 (Address = 01
Hex)
(MSB)
V15
SYMBOL
V7
V15
V0
V14
V6
POSITION
VCR1.7
VCR2.0
V13
V5
V12
NAME AND DESCRIPTION
V4
MSB of the 16-bit bipolar or code violation count.
LSB of the 16-bit bipolar or code violation count.
26 of 60
V11
V3
V10
V2
V9
V1
(LSB)
V8
V0
VCR1
VCR2

Related parts for DS2153QN-A7/T&R