MC9S12HZ128VAL Freescale Semiconductor, MC9S12HZ128VAL Datasheet - Page 302

IC MCU 16BIT 2K FLASH 112-LQFP

MC9S12HZ128VAL

Manufacturer Part Number
MC9S12HZ128VAL
Description
IC MCU 16BIT 2K FLASH 112-LQFP
Manufacturer
Freescale Semiconductor
Series
HCS12r
Datasheet

Specifications of MC9S12HZ128VAL

Core Processor
HCS12
Core Size
16-Bit
Speed
25MHz
Connectivity
CAN, EBI/EMI, I²C, SCI, SPI
Peripherals
LCD, Motor control PWM, POR, PWM, WDT
Number Of I /o
85
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Eeprom Size
2K x 8
Ram Size
6K x 8
Voltage - Supply (vcc/vdd)
2.35 V ~ 5.5 V
Data Converters
A/D 16x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
112-LQFP
Processor Series
S12H
Core
HCS12
Data Bus Width
16 bit
Data Ram Size
6 KB
Interface Type
I2C/SCI/SPI
Maximum Clock Frequency
50 MHz
Number Of Programmable I/os
85
Number Of Timers
8
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
3rd Party Development Tools
EWHCS12
Minimum Operating Temperature
- 40 C
On-chip Adc
16-ch x 10-bit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC9S12HZ128VAL
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC9S12HZ128VAL
Manufacturer:
FREESCALE
Quantity:
20 000
Chapter 10 Stepper Stall Detector (SSDV1)
10.4.1.1
In blanking mode with no drive, one of the coils is masked from the sigma-delta converter, and if RTZ is
enabled (RTZE = 1), it is set up to recirculate its current. If RTZ is enabled (RTZE = 1), the other coil is
disconnected to prevent any loss of flux change that would occur when the motor starts moving before the
end of recirculation and start of integration. In blanking mode with no drive, the accumulator is initialized
to 0x0000 and the converter is in a reset state.
10.4.1.2
In blanking mode with drive, one of the coils is masked from the sigma-delta converter, and if RTZ is
enabled (RTZE = 1), it is set up to recirculate its current. If RTZ is enabled (RTZE = 1), the other coil is
driven. In blanking mode with drive, the accumulator is initialized to 0x0000 and the converter is in a reset
state.
10.4.1.3
In conversion mode, one of the coils is routed for integration with one end connected to the (non-zero)
reference input and the other end connected to the integrator input of the sigma-delta converter. If RTZ is
enabled (RTZE=1), both coils are disconnected. This mode is not useful for stall detection.
10.4.1.4
In integration mode, one of the coils is routed for integration with one end connected to the (non-zero)
reference input and the other end connected to the integrator input of the sigma-delta converter. If RTZ is
enabled (RTZE = 1), the other coil is driven. This mode is used to rectify and integrate the back EMF
produced by the coils to detect stepped rotary motion.
DC offset compensation is implemented when using the modulus down counter to monitor integration
time.
10.4.2
During a return to zero (RTZ) event, the stepper motor pointer requires a 90 full motor electrical step with
full amplitude pulses applied to each phase in turn. For counter clockwise rotation (CCW), the STEP value
is incremented 0, 1, 2, 3, 0 and so on, and for a clockwise rotation the STEP value is decremented 3, 2, 1,
0 and so on.
when DCOIL is set.
302
Full Step States
Figure 10-10
Blanking with No Drive
Blanking with Drive
Conversion
Integration
shows the current level through each coil for each full step in CCW rotation
0
0
1
1
Table 10-11. Return to Zero Modes
MC9S12HZ256 Data Sheet, Rev. 2.05
0
1
0
1
Blanking with no drive
Blanking with drive
Conversion
Integration
Freescale Semiconductor

Related parts for MC9S12HZ128VAL