82.031.0101.0 WIELAND ELECTRIC, 82.031.0101.0 Datasheet - Page 540

no-image

82.031.0101.0

Manufacturer Part Number
82.031.0101.0
Description
COUPLING MODULE
Manufacturer
WIELAND ELECTRIC
Datasheet

Specifications of 82.031.0101.0

Connector Type
Modular
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
cemos
Short closing/opening times
Wear resistant equipment
Electrical isolation
Dimensions (mm): W x H x D
60.8 x 80 x 63
538
Function module
DC motor contactor
cemos
Description
Electronic three phase contactor
Electronic reversing contactor
DC motor contactor
Wiring diagrams, derating curve, limit curve
Input
Operating voltage
Voltage range for “ON”
Voltage range for “OFF”
Nominal current for “ON“
Closed circuit current consumption
Pick up delay
Protection circuit of input
Status display: Start/Stop –H1 and direction –H3
Output
Nominal switching voltage
Maximum switching voltage
Minimum switching voltage
Maximum switching current
Minimum switching current
Motor voltage UA1
Motor voltage UA2
Motor peak current
Typical R
Fault indicator: excess temperature and overcurrent –H2
Maximum pickup delay
Maximum dropout delay
Isolation voltage between input/output
Ambient temperature
Storage temperature
Mounting rail
Wire range, finely stranded/single core
Wire range (load), finely stranded/single core
Location of mounting rail
Norms/specifications
Emitted interference
Interference immunity
DS
ON
24V DC / 3A
DC motor reversing contactor
Approvals:
Type
See pages 544-545
24 V DC
15...28 V DC
0...5 V DC
ca. 10 mA
ca. 25 mA
ca. 1 ms
Polarised diode
Green LED
24 V DC
28 V DC
20 V DC
3A DC (Derating)
10 mA
Terminal 6
Terminal 5
6 A (200 ms)
0,6 Ω
Red LED
5 ms
5 ms
4 kV
–25 °C...+50 °C
–25 °C...+55 °C
TS 35 and TS 32
TS 35
0.5 mm
0.5 mm
horizontal
horizontal
VDE 0160
EN 61000-6-3
EN 61000-2
eff
2
2
– 2.5 mm
– 4 mm
2
/ 0.5 mm
2
Part no.
99.801.3900.9
/ 0.5 mm
2
– 6 mm
2
– 4 mm
2
Std. pack
2
/ 22 – 12 AWG
/ 22 – 10 AWG
1
Important note:
In the case of motors that are controlled by solid-state
relays, an additional mechanical contact must be
connected in series for safety separation.
This mechanical contact can influence several motors.
The protection of the solid state component must be
guaranteed by a rapid reacting fuse.
Subject to change without further notice

Related parts for 82.031.0101.0