82.031.0101.0 WIELAND ELECTRIC, 82.031.0101.0 Datasheet - Page 822

no-image

82.031.0101.0

Manufacturer Part Number
82.031.0101.0
Description
COUPLING MODULE
Manufacturer
WIELAND ELECTRIC
Datasheet

Specifications of 82.031.0101.0

Connector Type
Modular
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
facts
facts
Tables, technical data, explanations
Table 1: Degrees of protection against access to dangerous components, identified by the first identification number
820
Components of the IP code and its meaning
A short description of the IP code components is given in the following table:
First identification
Second identification number
First identification number
number
Identification letter
0
1
2
3
4
5
6
Component
Note:
Brief description
unprotected
protected against access to dangerous components
with the back of the hand
protected against access to dangerous components
with a finger
protected against access to dangerous components
with a tool
protected against access to dangerous components
with a wire
protected against access to dangerous components
with a wire
protected against access to dangerous components
with a wire
& DATA
For the first identification numbers 3, 4, 5 and 6 protection against access to dangerous components is provided if
a sufficient distance is maintained. Due to the simultaneously applicable requirement according to table 2, the
definition “must not penetrate” was given in table 1.
Figures or
letter
IP
0
1
2
3
4
5
6
0
1
2
3
4
5
6
7
8
Meaning for the protection of the equipment
against ingress of solid foreign bodies
(unprotected)
≥ 50
≥ 12.5 mm
≥ 2.5 mm
≥ 1.0 mm
protected against dust
dustproof
against ingress of water with damaging
effects
(unprotected)
dripping water falling vertically
dripping water (15° slope)
spraying water
splashing water
jet water
powerful jet water
temporary submersion
continuous submersion
mm
diameter
diameter
diameter
diameter
Degree of protection
Definition
The access probe, 50 mm diameter sphere, must be a
sufficient distance away from the dangerous components
The jointed test finger, 12 mm in diameter, 80 mm in length,
must be a sufficient distance away from the dangerous components
The access probe with a diameter of 2.5 mm
must not penetrate
The access probe with a diameter of 1.0 mm
must not penetrate
The access probe with a diameter of 1.0 mm
must not penetrate
The access probe with a diameter of 1.0 mm
must not penetrate
Meaning for the protection of
people:
against access to dangerous
components with
(unprotected)
back of hand
finger
tool
wire
wire
wire

Related parts for 82.031.0101.0