ISP1507BBS,118 NXP Semiconductors, ISP1507BBS,118 Datasheet - Page 30

no-image

ISP1507BBS,118

Manufacturer Part Number
ISP1507BBS,118
Description
RF Transceiver USB 2.0 ULPI TRNSCVR
Manufacturer
NXP Semiconductors
Datasheet

Specifications of ISP1507BBS,118

Number Of Transceivers
1
Esd Protection
YeskV
Power Supply Requirement
Single
Operating Supply Voltage (typ)
3.3V
Operating Temperature Classification
Industrial
Operating Supply Voltage (max)
3.6V
Operating Supply Voltage (min)
3V
Dual Supply Voltage (typ)
Not RequiredV
Dual Supply Voltage (max)
Not RequiredV
Dual Supply Voltage (min)
Not RequiredV
Pin Count
32
Mounting
Surface Mount
Operating Temperature (max)
85C
Operating Temperature (min)
-40C
Lead Free Status / RoHS Status
Compliant
Other names
935285495118 ISP1507BBS-T
NXP Semiconductors
ISP1507A_ISP1507B_1
Product data sheet
9.5.2.3 Using and selecting the V
The V
link whenever there is a change in the V
must first enable the corresponding interrupts in the USB_INTR_EN_R_E and
USB_INTR_EN_F_E registers.
The link can use the V
shows the recommended usage for typical applications.
Table 15.
Standard USB host controllers:
500 mA on V
detect overcurrent conditions. If the external overcurrent detector provides a digital fault
signal, then the fault signal must be connected to the ISP1507 FAULT input pin, and the
link must do the following:
Standard USB peripheral controllers:
when V
start and end of USB peripheral operations. Detection of A_VBUS_VLD and SESS_END
thresholds is not needed for standard peripherals.
Application
Standard host
Standard peripheral no
OTG A-device
OTG B-device
1. Set the IND_COMPL bit in the INTF_CTRL register (see
2. Set the USE_EXT_VBUS_IND bit in the OTG_CTRL register (see
3. If it is not necessary to qualify the fault indicator with the internal A_VBUS_VLD
Fig 11. RXCMD A_VBUS_VLD indicator source
USE_EXT_VBUS_IND,
logic 1, depending on the polarity of the external fault signal.
logic 1.
comparator, set the IND_PASSTHRU bit in the INTF_CTRL register to logic 1.
BUS
IND_PASSTHRU
BUS
IND_COMPL
state encoding is shown in
V
is at a sufficient level for operation. SESS_VLD must be enabled to detect the
BUS
BUS
FAULT
V
indicators in RXCMD required for typical applications
BUS
in the range of 4.75 V to 5.25 V. An external circuit must be used to
A_VBUS_VLD comparator
A_VBUS_VLD
yes
yes
no
FAULT indicator
BUS
Rev. 01 — 19 May 2008
state to monitor V
BUS
state encoding
internal A_VBUS_VLD
For standard hosts, the system must be able to provide
Table
BUS
SESS_VLD
no
yes
yes
yes
Standard peripherals must be able to detect
11. The ISP1507 will send an RXCMD to the
state. To receive V
BUS
ISP1507A; ISP1507B
complement
and take appropriate action.
output
ULPI HS USB OTG transceiver
SESS_END
no
no
no
yes
Section
BUS
state updates, the link
004aaa698
(0, X)
(1, 0)
(1, 1)
10.1.3) to logic 0 or
Section
© NXP B.V. 2008. All rights reserved.
RXCMD
A_VBUS_VLD
Table 15
10.1.4) to
29 of 81

Related parts for ISP1507BBS,118