MC9S08DZ16 FREESCALE [Freescale Semiconductor, Inc], MC9S08DZ16 Datasheet - Page 162

no-image

MC9S08DZ16

Manufacturer Part Number
MC9S08DZ16
Description
8-Bit HCS08 Central Processor Unit (CPU)
Manufacturer
FREESCALE [Freescale Semiconductor, Inc]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC9S08DZ16ACLC
Manufacturer:
FREESCALE
Quantity:
2 300
Part Number:
MC9S08DZ16ACLC
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC9S08DZ16ACLC
Manufacturer:
FREESCALE
Quantity:
2 300
Part Number:
MC9S08DZ16ACLF
Manufacturer:
FREESCALE
Quantity:
4 320
Part Number:
MC9S08DZ16ACLF
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC9S08DZ16MLC
Quantity:
2 090
Chapter 8 Multi-Purpose Clock Generator (S08MCGV1)
162
3. Then, BLPE mode transitions into PBE mode:
4. Last, PBE mode transitions into PEE mode:
c) MCGC1 = 0x98 (%10011000)
d) MCGC3 = 0x44 (%01000100)
e) Loop until PLLST (bit 5) in MCGSC is set, indicating that the current source for the PLLS
a) Clear LP (bit 3) in MCGC2 to 0 here to switch to PBE mode
b) Then loop until LOCK (bit 6) in MCGSC is set, indicating that the PLL has acquired lock
a) MCGC1 = 0x18 (%00011000)
b) Loop until CLKST (bits 3 and 2) in MCGSC are %11, indicating that the PLL output is selected
– RDIV (bits 5-3) set to %011, or divide-by-8 because 8 MHz / 8= 1 MHz which is in the 1
– PLLS (bit 6) set to 1, selects the PLL. In BLPE mode, changing this bit only prepares the
– VDIV (bits 3-0) set to %0100, or multiply-by-16 because 1 MHz reference * 16 = 16 MHz.
clock is the PLL
– CLKS (bits7 and 6) in MCGSC1 set to %00 in order to select the output of the PLL as the
to feed MCGOUT in the current clock mode
– Now, With an RDIV of divide-by-8, a BDIV of divide-by-1, and a VDIV of multiply-by-16,
MHz to 2 MHz range required by the PLL. In BLPE mode, the configuration of the RDIV
does not matter because both the FLL and PLL are disabled. Changing them only sets up the
the dividers for PLL usage in PBE mode
MCG for PLL usage in PBE mode
In BLPE mode, the configuration of the VDIV bits does not matter because the PLL is
disabled. Changing them only sets up the multiply value for PLL usage in PBE mode
system clock source
MCGOUT = [(8 MHz / 8) * 16] / 1 = 16 MHz, and the bus frequency is MCGOUT / 2, or 8
MHz