HD6433044 Hitachi Semiconductor, HD6433044 Datasheet - Page 358

no-image

HD6433044

Manufacturer Part Number
HD6433044
Description
(HD64 Series) Hitachi Single-Chip Microcomputer
Manufacturer
Hitachi Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6433044A00FV
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6433044F16
Manufacturer:
HITACHI
Quantity:
5 530
Part Number:
HD6433044F16
Manufacturer:
IDT
Quantity:
3 198
Part Number:
HD6433044F16
Manufacturer:
HITACHI
Quantity:
648
Part Number:
HD6433044F16A00
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6433044F18
Manufacturer:
HITACHI
Quantity:
5 530
Part Number:
HD6433044F18
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6433044F18
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6433044F18M08
Manufacturer:
TI
Quantity:
403
Part Number:
HD6433044F18M08
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6433044F18M08
Manufacturer:
HITACHI/日立
Quantity:
20 000
10.4.3 Synchronization
The synchronization function enables two or more timer counters to be synchronized by writing
the same data to them simultaneously (synchronous preset). With appropriate TCR settings, two or
more timer counters can also be cleared simultaneously (synchronous clear). Synchronization
enables additional general registers to be associated with a single time base. Synchronization can
be selected for all channels (0 to 4).
Sample Setup Procedure for Synchronization: Figure 10-26 shows a sample procedure for
setting up synchronization.
1.
2.
3.
4.
5.
Set the SYNC bits to 1 in TSNC for the channels to be synchronized.
When a value is written in TCNT in one of the synchronized channels, the same value is
simultaneously written in TCNT in the other channels (synchronized preset).
Set the CCLR1 or CCLR0 bit in TCR to have the counter cleared by compare match or input capture.
Set the CCLR1 and CCLR0 bits in TCR to have the counter cleared synchronously.
Set the STR bits in TSTR to 1 to start the synchronized counters.
Setup for synchronization
Select synchronization
Synchronous preset
Synchronous preset
Write to TCNT
Figure 10-26 Setup Procedure for Synchronization (Example)
1
2
Select counter clear source
synchronized to this
Synchronous clear
Counter clear
Start counter
channel?
Clearing
346
Yes
3
5
No
Select counter clear source
Synchronous clear
Start counter
4
5

Related parts for HD6433044