UPSD3433E-40U6 STMicroelectronics, UPSD3433E-40U6 Datasheet - Page 251

no-image

UPSD3433E-40U6

Manufacturer Part Number
UPSD3433E-40U6
Description
MCU 8BIT 8032 128KB FLASH 80TQFP
Manufacturer
STMicroelectronics
Series
µPSDr
Datasheet

Specifications of UPSD3433E-40U6

Core Processor
8032
Core Size
8-Bit
Speed
40MHz
Connectivity
I²C, IrDA, SPI, UART/USART, USB
Peripherals
LVD, POR, PWM, WDT
Number Of I /o
46
Program Memory Size
160KB (160K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
80-TQFP, 80-VQFP
For Use With
497-5518 - EVAL BOARD RFID READER497-5218 - KIT DEVELOPMENT FOR UPSD3400497-2381 - CABLE PROGRAMMER FLASH LINK
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Other names
497-4907

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPSD3433E-40U6
Manufacturer:
DENSO
Quantity:
83
Part Number:
UPSD3433E-40U6
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
UPSD3433E-40U6
Manufacturer:
ST
0
UPSD3422, UPSD3433, UPSD3434, UPSD3454
28.5.54
are driving the address lines. The PLDs will also stay in standby mode if the PLDs are in
non-Turbo mode and if all other PLD inputs (non-address signals) are static.
However, if the ALE signal has a transition before the APD counter reaches max count, the
APD counter is cleared to zero and the PDN signal will not go active, preventing power-
down mode. To prevent unwanted APD time-outs during normal 8032 operation (not
sleeping), it is important to choose a clock frequency for CLKIN that will NOT produce 15 or
more pulses within the longest period between ALE transitions. A 32768 Hz clock signal is
quite often an ideal frequency for CLKIN and APD, and this frequency is often available on
external supervisor or real-time clock devices.
The “PDN” power-down indicator signal is available to the PLD input bus to use in any PLD
equations if desired. The user may want to send this signal as a PLD output to an external
device to indicate the PSD module is in power-down mode. PSDsoft Express automatically
includes the “PDN” signal in the DPLD chip select equations for FSx, CSBOOTx, RS0, and
CSIOP.
The following should be kept in mind when the PSD module is in power-down mode:
The APD counter will count whenever Bit 1 of csiop PMMR0 register is set to logic '1,' and
when the ALE signal is steady at either logic ’1’ or logic ’0’ (not transitioning).
page 253
PSDsoft Express to enable APD mode is to select the pin function “Common Clock Input,
CLKIN” before programming with JTAG.
Forced power-down (FDP)
An alternative to APD is FPD. The resulting power-savings is the same, but the PDN signal
in
firmware sets the FORCE_PD Bit to logic '1' in the csiop register PMMR3 (Bit 1). FPD will
override APD counter activity when FORCE_PD is set. No external clock source for the APD
counter is needed. The FORCE_PD Bit is cleared only by a reset condition.
Caution must be used when implementing FPD because code memory goes off-line as
soon as PSD module Power-Down mode is entered, leaving the MCU with no instruction
stream to execute.
The MCU module must put itself into Power-Down mode after it puts the PSD module into
Power-Down Mode. How can it do this if code memory goes off-line? The answer is the Pre-
Fetch Queue (PFQ) in the MCU module. By using the instruction scheme shown in the 8051
Figure 88 on page 252
8032 address and data bus signals are blocked from all memories and both PLDs.
The PSD module comes out of power-down mode when: ALE starts pulsing again, or
the CSI input on pin PD2 transitions from logic ’1’ to logic '0,' or the PSD module reset
signal, RST, transitions from logic ’0’ to logic '1.'
Various signals can be blocked (prior to power-down mode) from entering the PLDs by
using “blocking bits” in csiop PMMR registers.
The Flash memory enters standby mode, and the state of the PLDs and I/O Ports are
unchanged (if no PLD inputs change).
power-down mode on I/O pins while in various operating modes.
The 8032 Ports 1,3, and 4 on the MCU module are not affected at all by power-down
mode in the PSD module.
Power-down standby current given in the AC specifications for PSD module assume
there are no transitions on any unblocked PLD input, and there are no output pins
driving any loads.
shows the flow leading up to power-down mode. The only action required in
is set and Power-Down mode is entered immediately when
Table 203 on page 256
shows the effects of
Figure 89 on
PSD module
251/300

Related parts for UPSD3433E-40U6