PEB20256E-V21 Infineon Technologies, PEB20256E-V21 Datasheet - Page 118

IC CONTROLLER INTERFACE 388-BGA

PEB20256E-V21

Manufacturer Part Number
PEB20256E-V21
Description
IC CONTROLLER INTERFACE 388-BGA
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB20256E-V21

Function
Multichannel Network Interface Controller (MUNICH)
Interface
HDLC, PPP, Serial, TMA
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
200mA
Power (watts)
3W
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
388-BBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Circuits
-
Other names
PEB20256E-V21
PEB20256E-V21IN

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB20256E-V21
Manufacturer:
MAX
Quantity:
63
Part Number:
PEB20256E-V21
Manufacturer:
Infineon Technologies
Quantity:
10 000
The MUNICH256 will NOT generate a ’Transmit Command Complete’ interrupt vector
after this command is programmed.
Transmit Update FNUM
The
CSPEC_MODE_XMIT.FNUM in the internal channel database, which allows to change
dynamically the number of idle flags that are inserted between two frames.
The MUNICH256 will NOT generate a ’Transmit Command Complete’ interrupt vector
after this command is programmed.
Transmit Idle
The
CSPEC_MODE_XMIT.TFLAG in the time slots of the selected channel. This command
can only be given if a channel is turned off.
The MUNICH256 will NOT generate a ’Transmit Command Complete’ interrupt vector
after this command is programmed.
Transmit Debug
The ’Transmit Debug’ command allows to read back the current settings of the internal
channel database. After the ’Transmit Debug’ command has been programmed system
software can read back the current values of the channel specification registers. Register
CSPEC_FTDA contains the value of the next transmit descriptor.
The MUNICH256 will NOT generate a ’Transmit Command Complete’ interrupt vector
after this command is programmed.
Note: The setting of the internal channel database is not copied into the channel
6.3
Receive Init
Before a ’Receive Init’ command is given, the MUNICH256 will not process data for a
channel. After the ’Receive Init’ command the channel database of the affected channel
is initialized according to the parameters programmed in channel specification registers.
After initialization data received in those time slots assigned to the selected channel is
processed and stored in the internal receive buffer. The data management unit starts
storing this data in the linked list which starts at CSPEC_FRDA. The protocol machine
deformats and checks data according to the given channel parameters.
Data Sheet
’Transmit
specification registers and therefore the values read can not be used to program
another channel. After system software has used the ’Transmit Debug’ command
it must reprogram the channel specification registers to setup a new channel.
’Transmit
Receive Channel Commands
Idle’
Update
command
FNUM’
Channel Programming / Reprogramming Concept
starts
118
command
the
MUNICH256
changes
to
send
the
PEB 20256 E
PEF 20256 E
the
parameter
04.2001
value

Related parts for PEB20256E-V21