PM5380-BI PMC-Sierra, Inc., PM5380-BI Datasheet - Page 168

no-image

PM5380-BI

Manufacturer Part Number
PM5380-BI
Description
Network Interface, SATURN User Network Interface (8x155) Telecom Standard Product
Manufacturer
PMC-Sierra, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PM5380-BI
Manufacturer:
PMC
Quantity:
648
Part Number:
PM5380-BI
Manufacturer:
PMC
Quantity:
11
Proprietary and Confidential to PMC-Sierra, Inc., and for its customers’ internal use.
Document No.: PMC- 2010299, Issue 2
Register 0x02E, 0x12E, 0x22E, 0x32E, 0x42E, 0x52E, 0x62E, 0x72E:
BUSY:
RWB:
SSTB Indirect Access Trigger Register
The BUSY bit reports whether a previously initiated indirect read or write to a message
buffer has been completed. BUSY is set high upon writing to the SSTB Indirect Address
register, and stays high until the initiated access has completed. At which point, BUSY is
set low. This register should be polled to determine when new data is available in the SSTB
Indirect Data register.
The access control bit (RWB) selects between an indirect read or write access to the static
page of the section trace message buffer. When RWB is set high, a read access is initiated.
The data read can be found in the SSTB Indirect Data register. When RWB is set low, a
write access is initiated. The data in the SSTB Indirect Data register will be written to the
addressed location in the static page.
Bit
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Type
R
R/W
Function
BUSY
RWB
Unused
Unused
Unused
Unused
Unused
Unused
S/UNI®-8x155 ASSP Telecom Standard Product Data Sheet
Default
0
0
X
X
X
X
X
X
Released
168