XE8000EV108 Semtech, XE8000EV108 Datasheet - Page 133

EVAL BOARD FOR XE8806/XE8807

XE8000EV108

Manufacturer Part Number
XE8000EV108
Description
EVAL BOARD FOR XE8806/XE8807
Manufacturer
Semtech
Type
MCUr
Datasheets

Specifications of XE8000EV108

Contents
Fully Assembled Evaluation Board
For Use With/related Products
XE88LC06AMI026
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
18.1 Features
18.2 Overview
The Voltage Level Detector monitors the state of the system battery. It returns a logical high value (an interrupt) in
the status register if the supplied voltage drops below the user defined level (Vsb).
18.3 Register map
There are two registers in the VLD, namely RegVldCtrl and RegVldStat. Table 18-2 shows the mapping of control
bits and functionality of RegVldCtrl while Table 18-3 describes that for RegVldStat.
18.4 Interrupt map
© Semtech 2006
can be switched off, on or simultaneously with CPU activities
generates an interrupt if power supply is below a pre-determined level
pos.
7-3
2
1
0
pos.
7-4
3
2-0
RegVldStat
--
VldResult
VldValid
VldEn
RegVldCtrl
--
VldRange
VldTune[2:0]
interrupt source
IrqVld
rw
r
r
r
r w
rw
r
r w
r w
reset
00000
0 nresetglobal
0 nresetglobal
0 nresetglobal
reset
0000
0
nresetglobal
000
nresetglobal
register name
RegVldCtrl
RegVldStat
Table 18-4: Interrupt map
default mapping in the interrupt manager
Table 18-1: Vld registers
Table 18-3: RegVldStat
Table 18-2: RegVldCtrl
function
reserved
VLD detection voltage range for VldTune = “011”:
VLD tuning:
18-2
function
reserved
is 1 when battery voltage is below the detection
voltage
Indicates when VldResult can be read
VLD enable
000 : +19 %
111 : -18 %
0 : 1.3V
1 : 2.55V
RegIrqMid(2)
XE8806A/XE8807A
www.semtech.com

Related parts for XE8000EV108