EZ80F92AZ020EG Zilog, EZ80F92AZ020EG Datasheet - Page 172

IC ACCLAIM MCU 128KB 100LQFP

EZ80F92AZ020EG

Manufacturer Part Number
EZ80F92AZ020EG
Description
IC ACCLAIM MCU 128KB 100LQFP
Manufacturer
Zilog
Series
eZ80® Acclaim!®r
Datasheets

Specifications of EZ80F92AZ020EG

Core Processor
Z8
Core Size
8-Bit
Speed
20MHz
Connectivity
I²C, IrDA, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, WDT
Number Of I /o
24
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
100-LQFP
Processor Series
EZ80F92x
Core
eZ80
Data Bus Width
8 bit
Data Ram Size
8 KB
Interface Type
I2C, IrDA, SPI, UART
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
24
Number Of Timers
6
Operating Supply Voltage
3 V to 3.6 V
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Development Tools By Supplier
eZ80F920200ZCOG
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
Lead Free Status / Rohs Status
 Details
Other names
269-3871
EZ80F92AZ020EG

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EZ80F92AZ020EG
Manufacturer:
Zilog
Quantity:
10 000
eZ80F92/eZ80F93
Product Specification
165
ZDI Data Out
ZDI Data Out
(Read)
(Read)
ZCL
ZDA
Start Signal
Figure 40.ZDI Read Timing
ZDI Single-Bit Byte Separator
Following each 8-bit ZDI data transfer, a single-bit byte separator is used. To initiate a
new ZDI command, the single-bit byte separator must be High (logical 1) to allow for a
new ZDI START command to be sent. For all other cases, the single-bit byte separator can
be either Low (logical 0) or High (logical 1). When ZDI is configured to allow the CPU to
accept external bus requests, the single-bit byte separator should be Low (logical 0) during
all ZDI commands. This Low value indicates that ZDI is still operating and is not ready to
relinquish the Bus. The CPU does not accept the external bus requests until the single-bit
byte separator is a High (logical 1). For more information about accepting bus requests in
ZDI DEBUG mode, see the Bus Requests During ZDI DEBUG Mode section on page
169.
ZDI Register Addressing
Following a START signal the ZDI master must output the ZDI register address. All data
transfers with the ZDI block use special ZDI registers. The ZDI control registers that
reside in the ZDI register address space should not be confused with the eZ80F92 device
peripheral registers that reside in the I/O address space.
Many locations in the ZDI control register address space are shared by two registers, one
for Read Only access and one for Write Only access. As an example, a Read from ZDI
®
register address
returns the eZ80
Product ID Low Byte while a Write to this same
00h
location,
, stores the Low byte of one of the address match values used for generating
00h
BREAK points.
The format for a ZDI address is seven bits of address, followed by one bit for Read or
Write control, and completed by a single-bit byte separator. The ZDI executes a Read or
Write operation depending on the state of the R/W bit (0 = Write, 1 = Read). If no new
START command is issued at completion of the Read or Write operation, the operation
PS015313-0508
Zilog Debug Interface