HD6417727BP160CV Renesas Electronics America, HD6417727BP160CV Datasheet - Page 778

IC SH MPU ROMLESS 240BGA

HD6417727BP160CV

Manufacturer Part Number
HD6417727BP160CV
Description
IC SH MPU ROMLESS 240BGA
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417727BP160CV

Core Processor
SH-3 DSP
Core Size
32-Bit
Speed
160MHz
Connectivity
FIFO, SCI, SIO, SmartCard, USB
Peripherals
DMA, LCD, POR, WDT
Number Of I /o
104
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.7 V ~ 2.05 V
Data Converters
A/D 6x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
240-BGA
Package
240CSP
Family Name
SuperH
Maximum Speed
160 MHz
Operating Supply Voltage
1.8|3.3 V
Data Bus Width
32 Bit
Number Of Programmable I/os
104
Interface Type
SCI/USB
On-chip Adc
6-chx10-bit
On-chip Dac
2-chx8-bit
Number Of Timers
4
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417727BP160CV
Manufacturer:
LITEON
Quantity:
46 000
Part Number:
HD6417727BP160CV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 23 USB Function Controller
23.8.3
Automatic Stall by USB Function Module
When a stall setting is made with the Set Feature command, or in the event of a USB specification
violation, the USB function module automatically sets the internal status bit for the relevant
endpoint without regard to the USBEPSTL register, and returns a stall handshake (1-1 in figure
23.14).
Once an internal status bit is set, it remains set until cleared by a Clear Feature command from the
host, without regard to the USBEPSTL register. After a bit is cleared by the Clear Feature
command, USBEPSTL is referenced (3-1 in figure 23.14). The USB function module continues to
return a stall handshake while the internal status bit is set, since the internal status bit is set even if
a transaction is executed for the corresponding endpoint (2-1 and 2-2 in figure 23.14). To clear a
stall, therefore, the internal status bit must be cleared with a Clear Feature command (3-1 in figure
23.14). If set by the application, USBEPSTL should also be cleared (2-1 in figure 23.14).
Rev.6.00 Mar. 27, 2009 Page 720 of 1036