HD6417727BP160CV Renesas Electronics America, HD6417727BP160CV Datasheet - Page 814

IC SH MPU ROMLESS 240BGA

HD6417727BP160CV

Manufacturer Part Number
HD6417727BP160CV
Description
IC SH MPU ROMLESS 240BGA
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417727BP160CV

Core Processor
SH-3 DSP
Core Size
32-Bit
Speed
160MHz
Connectivity
FIFO, SCI, SIO, SmartCard, USB
Peripherals
DMA, LCD, POR, WDT
Number Of I /o
104
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.7 V ~ 2.05 V
Data Converters
A/D 6x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
240-BGA
Package
240CSP
Family Name
SuperH
Maximum Speed
160 MHz
Operating Supply Voltage
1.8|3.3 V
Data Bus Width
32 Bit
Number Of Programmable I/os
104
Interface Type
SCI/USB
On-chip Adc
6-chx10-bit
On-chip Dac
2-chx8-bit
Number Of Timers
4
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417727BP160CV
Manufacturer:
LITEON
Quantity:
46 000
Part Number:
HD6417727BP160CV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 24 USB HOST Module
Register: HcRhPortStatus[1:2]
Bits
1
0
Rev.6.00 Mar. 27, 2009 Page 756 of 1036
REJ09B0254-0600
Reset
0
0
R/W
R/W
R/W
Offset: 54–57, 58–5B
Description
(read) PortEnableStatus (PES)
This bit indicates whether the port is enabled or disabled. The
root hub clears this bit when the over-current condition and a
operational bus error such as disconnect event, power-off
switch, or babble is detected. PortEnabledStatusChange is set
by this change. This bit is set by writing SetPortEnable and
cleared by writing ClearPortEnable. This bit cannot be set when
CurrentConnectStatus is cleared. In addition, this bit is set upon
completion of the port reset by which ResetStatusChange is
set, or uponcompletion of the port suspend by which
SuspendStatusChange is set.
0 = Port disabled. (initial value)
1 = Port enabled.
(write) SetPortEnable
Writing a 1 sets PortEnableStatus. Writing a 0 has no effect.
If CurrentConnectStatus is cleared, this writing does not set
PortEnableStatus, instead, sets ConnectStatusChange. This
reports the driver that the power disconnection port has been
tried to be enabled.
(read) CurrentConnectStatus (CCS)
This bit indicates the status of the downstream port.
0 = No device connected.
1 = Device connected.
Note: If DeviceRemoveable is set (not removable) this bit is
always 1.
(write) ClearPortEnable
Writing a 1 clears PortEnableStatus. Writing a 0 has no effect.
CurrentConnectStatus is not affected by any writing.