Section 10 Multi-Function Timer Pulse Unit 2 (MTU2)
10.4
10.4.1
Each channel has a TCNT and TGR register. TCNT performs up-counting, and is also capable of
free-running operation, cycle counting, and external event counting.
Each TGR can be used as an input capture register or output compare register.
Always select MTU2 external pins set function using the pin function controller (PFC).
(1)
When one of bits CST0 to CST4 in TSTR or bits CSTU5, CSTV5, and CSTW5 in TSTR_5 is set
to 1, the TCNT counter for the corresponding channel begins counting. TCNT can operate as a
free-running counter, periodic counter, for example.
(a)
Figure 10.4 shows an example of the count operation setting procedure.
Rev. 2.00 Dec. 09, 2005 Page 496 of 1152
REJ09B0191-0200
Counter Operation
Example of Count Operation Setting Procedure
Operation
Basic Functions
Select counter clearing
Select output compare
Start count operation
Select counter clock
Operation selection
<Periodic counter>
Periodic counter
Figure 10.4 Example of Counter Operation Setting Procedure
Set period
register
source
[1]
[2]
[3]
[4]
[5]
<Free-running counter>
Free-running counter
Start count operation
[5]
[1] Select the counter clock
[2] For periodic counter
[3] Designate the TGR
[4] Set the periodic counter
[5] Set the CST bit in TSTR to
with bits TPSC2 to TPSC0
in TCR. At the same time,
select the input clock edge
with bits CKEG1 and
CKEG0 in TCR.
operation, select the TGR
to be used as the TCNT
clearing source with bits
CCLR2 to CCLR0 in TCR.
selected in [2] as an output
compare register by means
of TIOR.
cycle in the TGR selected
in [2].
1 to start the counter
operation.