16F876 Microchip Technology, 16F876 Datasheet - Page 25

no-image

16F876

Manufacturer Part Number
16F876
Description
28/40-pin 8-Bit CMOS FLASH Microcontrollers
Manufacturer
Microchip Technology
Datasheet
2.2.2.8
The Power Control (PCON) Register contains flag bits
to allow differentiation between a Power-on Reset
(POR), a Brown-out Reset (BOR), a Watch-dog Reset
(WDT) and an external MCLR Reset.
REGISTER 2-8: PCON REGISTER (ADDRESS 8Eh)
1999 Microchip Technology Inc.
bit7
bit 7-2: Unimplemented: Read as '0'
bit 1:
bit 0:
U-0
PCON REGISTER
POR: Power-on Reset Status bit
1 = No Power-on Reset occurred
0 = A Power-on Reset occurred (must be set in software after a Power-on Reset occurs)
BOR: Brown-out Reset Status bit
1 = No Brown-out Reset occurred
0 = A Brown-out Reset occurred (must be set in software after a Brown-out Reset occurs)
U-0
U-0
U-0
U-0
U-0
R/W-0
POR
Note:
bit0
R/W-1
BOR is unknown on POR. It must be set by
the user and checked on subsequent rests
to see if BOR is clear, indicating a brown-
out has occurred. The BOR status bit is a
don’t care and is not predictable if the
brown-out circuit is disabled (by clearing
the BODEN bit in the configuration word).
BOR
R = Readable bit
W = Writable bit
U = Unimplemented bit,
- n= Value at POR reset
PIC16F87X
read as ‘0’
DS30292B-page 25

Related parts for 16F876