D12350F20IV Renesas Electronics America, D12350F20IV Datasheet - Page 610

IC H8S/2350 MCU 4.5/5.5V 0+K I-T

D12350F20IV

Manufacturer Part Number
D12350F20IV
Description
IC H8S/2350 MCU 4.5/5.5V 0+K I-T
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheets

Specifications of D12350F20IV

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
87
Program Memory Type
ROMless
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
128-QFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
D12350F20IV
Manufacturer:
INF
Quantity:
4 834
Section 13 Serial Communication Interface (SCI)
13.3
13.3.1
The SCI can carry out serial communication in two modes: asynchronous mode in which
synchronization is achieved character by character, and clocked synchronous mode in which
synchronization is achieved with clock pulses.
Selection of asynchronous or clocked synchronous mode and the transmission format is made
using SMR as shown in table 13.8. The SCI clock is determined by a combination of the C/A bit
in SMR and the CKE1 and CKE0 bits in SCR, as shown in table 13.9.
Asynchronous Mode
Clocked Synchronous Mode
Rev. 3.00 Sep 15, 2006 page 574 of 988
REJ09B0330-0300
Data length: Choice of 7 or 8 bits
Choice of parity addition, multiprocessor bit addition, and addition of 1 or 2 stop bits (the
combination of these parameters determines the transfer format and character length)
Detection of framing, parity, and overrun errors, and breaks, during reception
Choice of internal or external clock as SCI clock source
Transfer format: Fixed 8-bit data
Detection of overrun errors during reception
Choice of internal or external clock as SCI clock source
When internal clock is selected:
The SCI operates on the baud rate generator clock and a clock with the same frequency as
the bit rate can be output
When external clock is selected:
A clock with a frequency of 16 times the bit rate must be input (the on-chip baud rate
generator is not used)
When internal clock is selected:
The SCI operates on the baud rate generator clock and a serial clock is output off-chip
When external clock is selected:
The on-chip baud rate generator is not used, and the SCI operates on the input serial clock
Operation
Overview

Related parts for D12350F20IV