SAK-XC866-1FRA AB Infineon Technologies, SAK-XC866-1FRA AB Datasheet - Page 102

no-image

SAK-XC866-1FRA AB

Manufacturer Part Number
SAK-XC866-1FRA AB
Description
IC MCU 8BIT FLASH 38-TSSOP
Manufacturer
Infineon Technologies
Series
XC8xxr
Datasheet

Specifications of SAK-XC866-1FRA AB

Core Processor
XC800
Core Size
8-Bit
Speed
86MHz
Connectivity
SSI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
19
Program Memory Size
4KB (4K x 8)
Program Memory Type
FLASH
Ram Size
768 x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 125°C
Package / Case
38-TSSOP
Data Bus Width
8 bit
Data Ram Size
750 B
Interface Type
UART, SSC
Maximum Clock Frequency
26.67 MHz
Number Of Programmable I/os
27
Number Of Timers
3
Operating Supply Voltage
3.3 V, 5 V
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 8 Channel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
SP000235420
4.2.4
Table 37
Parameter
Active Mode
Idle Mode
Active Mode with slow-down
enabled
Idle Mode with slow-down
enabled
1)
2)
3)
4)
5)
6)
Data Sheet
V
DDP
The typical
The maximum
I
on-chip oscillator of 10 MHz and NDIV in PLL_CON to 0010
I
enabled and running at 26.7 MHz, RESET =
I
at 833 KHz by setting CLKREL in CMCON to 0101
I
clock to all peripherals enabled and running at 833 KHz by setting CLKREL in CMCON to 0101
RESET =
DDP
DDP
DDP
DDP
(active mode with slow-down mode) is measured with: CPU clock and input clock to all peripherals running
(active mode) is measured with: CPU clock and input clock to all peripherals running at 26.7 MHz(set by
(idle mode) is measured with: CPU clock disabled, watchdog timer disabled, input clock to all peripherals
(idle mode with slow-down mode) is measured with: CPU clock disabled, watchdog timer disabled, input
= 5V Range
V
Power Supply Current
I
DDP
DDP
I
V
Power Supply Current Parameters (Operating Conditions apply;
, no load on ports.
DDP
values are periodically measured at
DDP
values are measured under worst case conditions (
= 5V range )
Symbol
I
I
I
I
DDP
DDP
DDP
DDP
V
DDP
, no load on ports.
B
22.6
17.2
12.5
7.2
5.6
7.1
5.1
98
, RESET =
typ.
T
Limit Values
A
= + 25 °C and
1)
B
), RESET =
24.5
19.7
14
8.2
7.5
8
7.2
V
max.
DDP
, no load on ports.
2)
V
T
DDP
A
V
= + 125 °C and
DDP
Unit
mA
mA
mA
mA
mA
mA
mA
= 5.0 V.
, no load on ports.
Electrical Parameters
Test Condition
Remarks
3)
XC866-4FR,
XC866-2FR
XC866-1FR,
ROM device
XC866-4FR,
XC866-2FR
XC866-1FR,
ROM device
XC866-4FR,
XC866-2FR
XC866-1FR,
ROM device
V
DDP
V1.2, 2007-10
= 5.5 V).
XC866
4)
5)
6)
4)
5)
6)
B
,