AD9995KCP Analog Devices Inc, AD9995KCP Datasheet - Page 32

IC CCD SIGNAL PROCESSOR 56-LFCSP

AD9995KCP

Manufacturer Part Number
AD9995KCP
Description
IC CCD SIGNAL PROCESSOR 56-LFCSP
Manufacturer
Analog Devices Inc
Type
CCD Signal Processor, 12-Bitr
Datasheet

Specifications of AD9995KCP

Rohs Status
RoHS non-compliant
Input Type
Logic
Output Type
Logic
Interface
3-Wire Serial
Current - Supply
30mA
Mounting Type
Surface Mount
Package / Case
56-LFCSP
Analog Front End Type
CCD
Analog Front End Category
Video
Interface Type
Serial (3-Wire)
Input Voltage Range
0.5V
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (typ)
3V
Operating Supply Voltage (max)
3.6V
Resolution
12b
Number Of Adc's
1
Power Supply Type
Analog/Digital
Operating Temp Range
-20C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
56
Package Type
LFCSP EP
Number Of Channels
1
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD9995KCP
Manufacturer:
ADI
Quantity:
148
Part Number:
AD9995KCPZ
Manufacturer:
ADI
Quantity:
24
Part Number:
AD9995KCPZRL7
Manufacturer:
SANYO
Quantity:
1 170
A/D Converter
The AD9995 uses a high performance ADC architecture
optimized for high speed and low power. Differential nonlinearity
(DNL) performance is typically better than 0.5 LSB. The ADC
uses a 2 V input range. See TPC 2 and TPC 3 for typical linearity
and noise performance plots for the AD9995.
Optical Black Clamp
The optical black clamp loop is used to remove residual offsets
in the signal chain and to track low frequency variations in the
CCD’s black level. During the optical black (shielded) pixel inter-
val on each line, the ADC output is compared with a fixed black
level reference, selected by the user in the Clamp Level register.
The value can be programmed between 0 LSB and 255 LSB in
256 steps. The resulting error signal is filtered to reduce noise,
and the correction value is applied to the ADC input through a
D/A converter. Normally, the optical black clamp loop is turned
on once per horizontal line, but this loop can be updated more
slowly to suit a particular application. If external digital clamp-
ing is used during the postprocessing, the AD9995 optical black
clamping may be disabled using Bit D2 in the OPRMODE regis-
ter. When the loop is disabled, the Clamp Level register may still
be used to provide programmable offset adjustment.
AD9995
–32–
The CLPOB pulse should be placed during the CCD’s optical
black pixels. It is recommended that the CLPOB pulse dura-
tion be at least 20 pixels wide to minimize clamp noise. Shorter
pulsewidths may be used, but clamp noise may increase, and the
ability to track low frequency variations in the black level will
be reduced. See the Horizontal Clamping and Blanking section
and the Horizontal Timing Sequence Example section for timing
examples.
Digital Data Outputs
The AD9995 digital output data is latched using the DOUT
PHASE register value, as shown in Figure 33. Output data timing
is shown in Figure 8a. It is also possible to leave the output latches
transparent so that the data outputs are valid immediately from
the A/D converter. Programming the AFE CONTROL register bit
D4 to 1 will set the output latches transparent. The data outputs
can also be disabled (three-stated) by setting the AFE CONTROL
register Bit D3 to 1.
The data output coding is normally straight binary, but the
coding my be changed to gray coding by setting the AFE CON-
TROL register Bit D5 to 1.
REV. 0

Related parts for AD9995KCP