RCLXT16706FE Intel, RCLXT16706FE Datasheet - Page 35

no-image

RCLXT16706FE

Manufacturer Part Number
RCLXT16706FE
Description
Manufacturer
Intel
Datasheet

Specifications of RCLXT16706FE

Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
2.97V
Operating Supply Voltage (max)
3.63V
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Lead Free Status / Rohs Status
Not Compliant
Datasheet
Table 4.
Pin Description (Sheet 21 of 66)
RRD
RRDC
RMD
RMDC
TRD
TRDC
TMD
TMDC
RROW
RMOW
RDOW
ROWBYC
ROWC
TROW
TMOW
NOTE: See notes 1, 2, and
Pin Name
51/155/622/2488 Mbit/s SONET/SDH Cell/Packet Interface — Intel IXF6048
G27
H30
F27
H26
E31
H31
L26
J26
J30
Pin
U2
Y4
R4
V6
R6
U1
LVTTL
Output
4 mA
LVTTL
Output
4 mA
LVTTL
Output
4 mA
LVTTL
Output
4 mA
LVTTL
Input
LVTTL
Output
4 mA
LVTTL
Input
LVTTL
Output
4 mA
LVTTL
Output
4 mA
LVTTL
Output
4 mA
LVTTL
Output
4 mA
LVTTL
Output
4 mA
LVTTL
Output
4 mA
LVTTL
Input
LVTTL
Input
Type
3
at the end of the table.
Receive RSOH D1-D3 Data. RRD is a 192-Kbit/s data output for the
received RSOH D1-D3 data.
RRD is clocked out by RRDC.
Receive RSOH D1-D3 Data Clock. RRDC is a 192-KHz reference
signal used to clock out the RRD data.
Receive MSOH D4-D12 Data. RMD is a 576-Kbit/s data output for the
received RSOH D4-D12 data.
RMD is clocked out by RMDC.
Receive MSOH D4-D12 Data Clock. RMDC is a 576-KHz reference
signal used to clock out the RMD data.
Transmit RSOH D1-D3 Data. TRD is a 192-Kbit/s data input for the
transmit RSOH D1-D3 data.
TRD is clocked in by TRDC.
Transmit RSOH D1-D3 Data Clock. TRDC is a 192-KHz reference
signal used to clock in the TRD data.
Transmit MSOH D4-D12 Data. TMD is a 576-Kbit/s data input for the
transmit RSOH D4-D12 data.
TMD is clocked in by TMDC.
Transmit MSOH D1-D3 Data Clock. TMDC is a 576-KHz reference
signal used to clock in the TMD data.
Receive RSOH E1 Orderwire. RROW is a 64-Kbit/s output for the
received orderwire byte E1.
RROW is synchronized with ROWBYC and clocked out by ROWC.
Receive MSOH E2 Orderwire. RMOW is a 64-Kbit/s output for the
received orderwire byte E2.
RMOW is synchronized with ROWBYC and clocked out by ROWC.
Receive MSOH F1 Orderwire. RDOW is a 64-Kbit/s output for the
received orderwire byte F1.
RDOW is synchronized with ROWBYC and clocked out by ROWC.
Receive RSOH and MSOH Orderwire Synchronization. ROWBYC is
an 8-KHz reference signal used to byte-synchronize the received E1, E2,
and F1 bytes (RROW, RMOW, and RDOW outputs).
Receive RSOH and MSOH Orderwire Clock. ROWC is a 64-KHz
reference signal used to clock out RROW, RMOW, and RDOW.
Transmit RSOH E1 Orderwire. TROW is a 64-Kbit/s input for the
transmitted orderwire byte E1.
TROW is synchronized with TOWBYC and clocked in by TOWC.
Transmit MSOH E2 Orderwire. TMOW is a 64-Kbit/s input for the
transmitted orderwire byte E2.
TMOW is synchronized with TOWBYC and clocked in by TOWC.
Description
35

Related parts for RCLXT16706FE