PEF 20550 H V2.1 Infineon Technologies, PEF 20550 H V2.1 Datasheet - Page 298

no-image

PEF 20550 H V2.1

Manufacturer Part Number
PEF 20550 H V2.1
Description
IC INTERFACE CTRLR PCM MQFP80
Manufacturer
Infineon Technologies
Series
ELIC®r
Datasheet

Specifications of PEF 20550 H V2.1

Function
Line Card Controller
Interface
ISDN, PCM
Number Of Circuits
1
Voltage - Supply
5V
Current - Supply
15mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
80-SQFP
Includes
Change Detection, Power-Up Reset Generation
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Other names
PEF20550HV2.1XT
PEF20550HV21XP
SP000007794
SP000007795
address in order to be transmitted in the subsequent odd CFI timeslot!
In upstream direction a change detection mechanism is active to search for changes in
the received C/I or SIG values. Upon a change, the address of the involved subscriber
is stored in a 9 byte deep FIFO (CIFIFO) and an interrupt (ISTA:SFI) is generated. The
C/I or SIG value out of the Control Memory. The address FIFO serves to increase the
latency time for the P to react to SFI interrupts. If several C/I or SIG changes occur
before the P executes the SFI interrupt handling routine, the addresses of the first
9 changes are stored in the CIFIFO and the corresponding C/I or SIG values are stored
in the control memory (CM). If more than 9 changes occur before the P reads the
CIFIFO, these additional changes are no longer updated in the control memory. This is
to prevent any loss of change information. These additional changes remain pending at
the serial interface. As soon as the P reads the CIFIFO, and thus, empties locations of
the FIFO, these pending changes are sequentially written to the CM and the
corresponding addresses to the FIFO. It is thus ensured that no change information is
lost even if, for example, all 32 subscribers simultaneously generate a change in their C/
I or SIG channel!
CFI timeslots which should be processed by the CS handler must first be initialized as
MF/CS channels with appropriate codes in the Control Memory code field (refer to
chapter 5.5.1).
5.5.2
If the configurable interface (CFI) of the ELIC is operated as IOM or SLD interface, it is
necessary to communicate with the connected subscriber circuits such as layer-1
transceivers (ISDN line cards) or codec filter devices (analog line cards) over the
Command/Indication (C/I) or the signaling (SIG) channel. In order to simplify this task the
ELIC has implemented the Control/Signaling Handler (CS Handler).
In downstream direction, the 4, 6 or 8 bit C/I or SIG value can simply be written to the
Control Memory data field which will then be repeatedly transmitted in every frame to the
subscriber circuit until a new value is loaded.
Note that the downstream C/I or SIG value must always be written to the even CM
Semiconductor Group
P can then first determine the CM address by reading the FIFO before reading the new
Control/Signaling (CS) Handler
298
Application Hints
PEB 20550
PEF 20550
01.96