SAM7S16 Atmel Corporation, SAM7S16 Datasheet - Page 500

no-image

SAM7S16

Manufacturer Part Number
SAM7S16
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7S16

Flash (kbytes)
16 Kbytes
Pin Count
48
Max. Operating Frequency
55 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
21
Ext Interrupts
21
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Uart
2
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
4
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
35.4
35.4.1
35.4.2
500
Typical Connection
SAM7S Series
USB Device Transceiver
VBUS Monitoring
Figure 35-2. Board Schematic to Interface USB Device Peripheral
The USB device transceiver is embedded in the product. A few discrete components are
required as follows:
Pullup enable/disable is done through a MOSFET controlled by a PIO. The pullup is enabled
when the PIO drives a 0. Thus PIO default state to 1 corresponds to a pullup disable. Once the
pullup is enabled, the host will force a device reset 100 ms later. Bus powered devices must
connect the pullup within 100 ms.
VBUS monitoring is required to detect host connection. VBUS monitoring is done using a stan-
dard PIO with internal pullup disabled. When the host is switched off, it should be considered as
a disconnect, the pullup must be disabled in order to prevent powering the host through the pull-
up resistor.
When the host is disconnected and the transceiver is enabled, then DDP and DDM are floating.
This may lead to over consumption. A solution is to connect 330 KΩ pulldowns on DP and DM.
These pulldowns do not alter DDP and DDM signal integrity.
PIO
PIO
DDM
DDP
• the application detects all device states as defined in chapter 9 of the USB specification;
• to reduce power consumption the host is disconnected
• for line termination.
– pullup enable/disable
– VBUS monitoring
5V Bus Monitoring
Pullup Control
0: Enable
1: Disable
47 K
27 K
R
R
EXT
EXT
330 K
330 K
3V3
1.5K
2
3
Connector
Type B
6175L–ATARM–28-Jul-11
1
4

Related parts for SAM7S16