SAM7S16 Atmel Corporation, SAM7S16 Datasheet - Page 713

no-image

SAM7S16

Manufacturer Part Number
SAM7S16
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7S16

Flash (kbytes)
16 Kbytes
Pin Count
48
Max. Operating Frequency
55 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
21
Ext Interrupts
21
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Uart
2
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
4
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
40.18.3.4
40.18.3.5
40.18.4
40.18.4.1
40.18.5
40.18.5.1
40.18.5.2
40.18.5.3
6175L–ATARM–28-Jul-11
Real Time Timer (RTT)
Serial Peripheral Interface (SPI)
PWM: Constraints on Duty Cycle Value
PWM: Behavior of CHIDx Status Bits in the PWM_SR Register
RTT: Possible Event Loss when Reading RTT_SR
SPI: Software Reset Must be Written Twice
SPI: Pulse Generation on SPCK
SPI: Bad tx_ready behavior when CSAAT=1 and SCBR = 1
Setting Channel Duty Cycle Register (PWM_CDTYx) at 0 in center aligned mode or at 0 or 1 in
left aligned mode may change the polarity of the signal.
Do not set PWM_CDTYx at 0 in center aligned mode.
Do not set PWM_CDTYx at 0 or 1 in left aligned mode.
Erratic behavior of the CHIDx status bit in the PWM_SR Register. When a channel is disabled
by writing in the PWM_DIS Register just after enabling it (before completion of a Clock Period of
the clock selected for the channel), the PWM line is internally disabled but the CHIDx status bit
in the PWM_SR stays at 1.
Do not disable a channel before completion of one period of the selected clock.
If an event (RTTINC or ALMS) occurs within the same slow clock cycle during which the
RTT_SR is read, the corresponding bit might be cleared. This can lead to the loss of this event.
The software must handle the RTT event as an interrupt and should not poll RTT_SR.
If a software reset (SWRSTin the SPI Control Register) is performed, the SPI may not work
properly (the clock is enabled before the chip select.
The SPI Control Register field, SWRST needs to be written twice to be set correctly.
In Master Mode, there is an additional pulse generated on SPCK when the SPI is configured as
follows:
None.
If the SPI is programmed with CSAAT = 1, SCBR(baudrate) = 1 and two transfers are performed
consecutively on the same slave with an IDLE state between them, the tx_ready signal does not
rise after the second data has been transferred in the shifter. This can imply for example, that
the second data is sent twice.
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround:
Problem Fix/Workaround
Problem Fix/Workaround
– The Baudrate is odd and different from 1
– The Polarity is set to 1
– The Phase is set to 0
SAM7S Series
713

Related parts for SAM7S16