SAM7S16 Atmel Corporation, SAM7S16 Datasheet - Page 642

no-image

SAM7S16

Manufacturer Part Number
SAM7S16
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7S16

Flash (kbytes)
16 Kbytes
Pin Count
48
Max. Operating Frequency
55 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
21
Ext Interrupts
21
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Uart
2
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
4
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
40.8.8.5
40.8.9
40.8.9.1
40.8.9.2
40.8.9.3
40.8.9.4
40.8.9.5
642
SAM7S Series
Universal Synchronous Asynchronous Receiver Transmitter (USART)
TWI: Possible Receive Holding Register Corruption
USART: CTS in Hardware Handshaking
USART: Hardware Handshaking – Two Characters Sent
USART: XOFF Character Bad Behavior
USART: RXBRK Flag Error in Asynchronous Mode
USART: DCD is active High instead of Low
TXCOMP and NACK fields are set simultaneously and the NACK field is reset after the read of
the TWI_SR.
When loading the TWI_RHR, the transfer direction is ignored. The last data byte received in the
TWI_RHR is corrupted at the end of the first subsequent transmit data byte. Neither RXRDY nor
OVERRUN status bits are set if this occurs.
The user must be sure that received data is read before transmitting any new data.
When Hardware Handshaking is used and if CTS goes low near the end of the starting bit, a
character can be lost.
CTS must not go low during a time slot occurring between 2 Master Clock periods before the
starting bit and 16 Master Clock periods after the rising edge of the starting bit.
If CTS switches from 0 to 1 during the TX of a character and if the holding register (US_THR) is
not empty, the content of US_THR will also be transmitted.
Don't use the PDC in transmit mode and do not fill US_THR before TXEMPTY is set at 1.
The XOFF character is sent only when the receive buffer is detected full. While the XOFF is
being sent, the remote transmitter is still transmitting. As only one Holding register is available in
the receiver, characters will be lost in reception. This makes the software handshaking function-
ality ineffective.
None.
In receiver mode, when there are two consecutive characters (without timeguard in between),
RXBRK is not taken into account. As a result, the RXBRK flag is not enabled correctly and the
frame error flag is set.
Constraints on the transmitter device connected to the SAM7S USART receiver side:
The transmitter may use the timeguard feature or send two STOP conditions. Only one STOP
condition is taken into account by the receiver state machine. After this STOP condition, as there
is no valid data, the receiver state machine will go in idle mode and enable the RXBRK flag.
The DCD signal is active at High level in the USART Modem Mode.
DCD should be active at Low level.
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
6175L–ATARM–28-Jul-11