SAM7S16 Atmel Corporation, SAM7S16 Datasheet - Page 671

no-image

SAM7S16

Manufacturer Part Number
SAM7S16
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7S16

Flash (kbytes)
16 Kbytes
Pin Count
48
Max. Operating Frequency
55 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
21
Ext Interrupts
21
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Uart
2
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
4
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
40.12.4
40.12.4.1
40.12.4.2
40.12.4.3
40.12.4.4
40.12.4.5
40.12.5
40.12.5.1
6175L–ATARM–28-Jul-11
Pulse Width Modulation Controller (PWM)
Real Time Timer (RTT)
PWM: Update when PWM_CCNTx = 0 or 1
PWM: Update when PWM_CPRDx = 0
PWM: Counter Start Value
PWM: Constraints on Duty Cycle Value
PWM: Behavior of CHIDx Status Bits in the PWM_SR Register
RTT: Possible Event Loss when Reading RTT_SR
If the Channel Counter Register value is 0 or 1, the Channel Period Register or Channel Duty
Cycle Register is directly modified when writing the Channel Update Register.
Check the Channel Counter Register before writing the update register.
When Channel Period Register equals 0, the period update is not operational.
Do not write 0 in the period register.
In left aligned mode, the first start value of the counter is 0. For the other periods, the counter
starts at 1.
None.
Setting Channel Duty Cycle Register (PWM_CDTYx) at 0 in center aligned mode or at 0 or 1 in
left aligned mode may change the polarity of the signal.
Do not set PWM_CDTYx at 0 in center aligned mode.
Do not set PWM_CDTYx at 0 or 1 in left aligned mode.
Erratic behavior of the CHIDx status bit in the PWM_SR Register. When a channel is disabled
by writing in the PWM_DIS Register just after enabling it (before completion of a Clock Period of
the clock selected for the channel), the PWM line is internally disabled but the CHIDx status bit
in the PWM_SR stays at 1.
Problem Fix/Workaround
Do not disable a channel before completion of one period of the selected clock.
If an event (RTTINC or ALMS) occurs within the same slow clock cycle during which the
RTT_SR is read, the corresponding bit might be cleared. This can lead to the loss of this event.
The software must handle the RTT event as an interrupt and should not poll RTT_SR.
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround:
SAM7S Series
671