SAM7S16 Atmel Corporation, SAM7S16 Datasheet - Page 621

no-image

SAM7S16

Manufacturer Part Number
SAM7S16
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7S16

Flash (kbytes)
16 Kbytes
Pin Count
48
Max. Operating Frequency
55 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
21
Ext Interrupts
21
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Uart
2
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
4
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
40.6.11.2
40.6.11.3
40.6.11.4
40.6.11.5
40.6.12
40.6.12.1
40.6.12.2
6175L–ATARM–28-Jul-11
Universal Synchronous Asynchronous Receiver Transmitter (USART)
TWI: Software Reset
TWI: Disabling Does not Operate Correctly
TWI: NACK Status Bit Lost
TWI: Possible Receive Holding Register Corruption
USART: CTS in Hardware Handshaking
USART: Hardware Handshaking – Two Characters Sent
When a software reset is performed during a frame and when TWCK is low, it is impossible to
initiate a new transfer in READ or WRITE mode.
None.
Any transfer in progress is immediately frozen if the Control Register (TWI_CR) is written with
the bit MSDIS at 1. Furthermore, the status bits TXCOMP and TXRDY in the Status Register
(TWI_SR) are not reset.
The user must wait for the end of transfer before disabling the TWI. In addition, the interrupts
must be disabled before disabling the TWI.
During a master frame, if TWI_SR is read between the Non Acknowledge condition detection
and the TXCOMP bit rising in the TWI_SR, the NACK bit is not set.
The user must wait for the TXCOMP status bit by interrupt and must not read the TWI_SR as
long as transmission is not completed.
TXCOMP and NACK fields are set simultaneously and the NACK field is reset after the read of
the TWI_SR.
When loading the TWI_RHR, the transfer direction is ignored. The last data byte received in the
TWI_RHR is corrupted at the end of the first subsequent transmit data byte. Neither RXRDY nor
OVERRUN status bits are set if this occurs.
The user must be sure that received data is read before transmitting any new data.
When Hardware Handshaking is used and if CTS goes low near the end of the starting bit, a
character can be lost.
CTS must not go low during a time slot occurring between 2 Master Clock periods before the
starting bit and 16 Master Clock periods after the rising edge of the starting bit.
If CTS switches from 0 to 1 during the TX of a character and if the holding register (US_THR) is
not empty, the content of US_THR will also be transmitted.
Don't use the PDC in transmit mode and do not fill US_THR before TXEMPTY is set at 1.
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
Problem Fix/Workaround
SAM7S Series