ADUC832 Analog Devices, ADUC832 Datasheet - Page 10

no-image

ADUC832

Manufacturer Part Number
ADUC832
Description
Precision Analog Microcontroller: 1.3MIPS 8052 MCU + 62kB Flash + 8-Ch 12-Bit ADC + Dual 12-Bit DAC
Manufacturer
Analog Devices
Datasheet

Specifications of ADUC832

Mcu Core
8052
Mcu Speed (mips)
1.3
Sram (bytes)
2304Bytes
Gpio Pins
34
Adc # Channels
8
Other
PWM

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUC832BCPZ-REEL
Manufacturer:
ADI
Quantity:
208
Part Number:
ADUC832BS
Manufacturer:
ADI
Quantity:
150
Part Number:
ADUC832BSZ
Manufacturer:
SONY
Quantity:
101
Part Number:
ADUC832BSZ
Manufacturer:
ADI
Quantity:
150
Part Number:
ADUC832BSZ
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
ADUC832BSZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADUC832BSZ-REEL
Manufacturer:
Analog Devices Inc
Quantity:
10 000
ADuC832
TIMING SPECIFICATIONS
AV
Table 2. Clock Input (External Clock Applied on XTAL1)
Parameter
t
t
t
t
t
1/t
t
t
1
2
3
4
5
6
CK
CKL
CKH
CKR
CKF
CORE
CYC
AC inputs during testing are driven at DV
a Logic 0, as shown in Figure 4.
For timing purposes, a port pin is no longer floating when a 100 mV change from load voltage occurs. A port pin begins to float when a 100 mV change from the
loaded V
C
The ADuC832 internal PLL locks onto a multiple (512 times) the external crystal frequency of 32.768 kHz to provide a stable 16.78 MHz internal clock for the system.
The core can operate at this frequency or at a binary submultiple called Core_CLK, selected via the PLLCON SFR.
This number is measured at the default Core_CLK operating frequency of 2.09 MHz.
ADuC832 machine cycle time is nominally defined as 12/Core_CLK.
LOAD
CORE
DD
for all outputs = 80 pF, unless otherwise noted.
= 2.7 V to 3.6 V or 4.75 V to 5.25 V, DV
OH
/V
1, 2, 3
OL
level occurs, as shown in Figure 4.
DV
DD
–0.5V
0.45V
Description
XTAL1 period (see Figure 3)
XTAL1 width low (see Figure 3)
XTAL1 width high (see Figure 3)
XTAL1 rise time (see Figure 3)
XTAL1 fall time (see Figure 3)
ADuC832 core clock frequency
ADuC832 core clock period
ADuC832 machine cycle time
DD
− 0.5 V for a Logic 1 and 0.45 V for a Logic 0. Timing measurements are made at V
0.2DV
0.2DV
TEST POINTS
DD
DD
DD
= 2.7 V to 3.6 V or 4.75 V to 5.25 V; all specifications T
+ 0.9V
– 0.1V
t
CKH
Figure 4. Timing Waveform Characteristics
5
6
4
Figure 3. XTAL1 Input
Rev. A | Page 10 of 92
V
LOAD
t
CKL
V
V
LOAD
LOAD
+ 0.1V
– 0.1V
t
CKR
t
CK
0.131
0.72
Min
REFERENCE
POINTS
TIMING
32.768 kHz External Crystal
t
CKF
Typ
30.52
15.16
15.16
20
20
0.476
5.7
MIN
to T
IH
V
V
LOAD
LOAD
minimum for a Logic 1 and V
MAX
– 0.1V
+ 0.1V
, unless otherwise noted.
V
Max
16.78
91.55
LOAD
IL
maximum for
Unit
μs
μs
μs
ns
ns
MHz
μs
μs