ISP1362EE/01 PHILIPS [NXP Semiconductors], ISP1362EE/01 Datasheet - Page 88

no-image

ISP1362EE/01

Manufacturer Part Number
ISP1362EE/01
Description
Single-chip Universal Serial Bus On-The-Go controller
Manufacturer
PHILIPS [NXP Semiconductors]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISP1362EE/01
Manufacturer:
KAWASAKI
Quantity:
1 200
Part Number:
ISP1362EE/01
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Philips Semiconductors
9397 750 12337
Product data
Table 62:
Bit
31 to 21
20
19
18
17
16
15 to 10
HcRhPortStatus[1:2] register: bit description
Symbol
-
PRSC
OCIC
PSSC
PESC
CSC
-
Rev. 03 — 06 January 2004
Description
reserved
PortResetStatusChange: This bit is set at the end of the 10 ms
port reset signal. The HCD can write logic 1 to clear this bit.
Writing logic 0 has no effect.
0 — port reset is not complete
1 — port reset is complete
PortOverCurrentIndicatorChange: This bit is valid only if
overcurrent conditions are reported on a per-port basis. This bit is
set when the Root Hub changes the PortOverCurrentIndicator
(POCI) bit. The HCD can write logic 1 to clear this bit. Writing
logic 0 has no effect.
0 — no change in PortOverCurrentIndicator (POCI)
1 — PortOverCurrentIndicator (POCI) has changed
PortSuspendStatusChange: This bit is set when the full resume
sequence is complete. This sequence includes the 20 ms resume
pulse, LS EOP and 3 ms re-synchronization delay. The HCD can
write logic 1 to clear this bit. Writing logic 0 has no effect. This bit is
also cleared when ResetStatusChange is set.
0 — resume is not completed
1 — resume is completed
PortEnableStatusChange: This bit is set when hardware events
cause the PortEnableStatus (PES) bit to be cleared. Changes from
the HCD writes do not set this bit. The HCD can write logic 1 to
clear this bit. Writing logic 0 has no effect.
0 — no change in PortEnableStatus (PES)
1 — change in PortEnableStatus (PES)
ConnectStatusChange: This bit is set whenever a connect or
disconnect event occurs. The HCD can write logic 1 to clear this
bit. Writing logic 0 has no effect. If CurrentConnectStatus (CCS) is
cleared when a SetPortReset, SetPortEnable or SetPortSuspend
write occurs, this bit is set to force the driver to re-evaluate the
connection status because these writes should not occur if the port
is disconnected.
0 — no change in CurrentConnectStatus (CCS)
1 — change in CurrentConnectStatus (CCS)
Remark: If the DeviceRemovable[NDP] bit is set, this bit is set only
after a Root Hub reset to inform the system that the device is
attached.
reserved
Single-chip USB OTG controller
© Koninklijke Philips Electronics N.V. 2004. All rights reserved.
ISP1362
88 of 150

Related parts for ISP1362EE/01