7.4.8
7.5
7.5.1
7.6
SMSC/Non-SMSC Register Sets (Rev. 01-11-07)
EPP Data Port 3
ADDRESS OFFSET = 07H
The EPP Data Port 3 is located at an offset of ‘07H’ from the base address. Refer to EPP DATA PORT 0
for a description of operation. This register is only available in EPP mode.
EPP 1.9 Operation
When the EPP mode is selected in the configuration register, the standard and bi-directional modes are
also available. If no EPP Read, Write or Address cycle is currently executing, then the PDx bus is in the
standard or bi-directional mode, and all output signals (STROBE, AUTOFD, INIT) are as set by the SPP
Control Port and direction is controlled by PCD of the Control port.
In EPP mode, the system timing is closely coupled to the EPP timing. For this reason, a watchdog timer is
required to prevent system lockup. The timer indicates if more than 10usec have elapsed from the start of
the EPP cycle to nWAIT being deasserted (after command). If a time-out occurs, the current EPP cycle is
aborted and the time-out condition is indicated in Status bit 0.
During an EPP cycle, if STROBE is active, it overrides the EPP write signal forcing the PDx bus to always
be in a write mode and the nWRITE signal to always be asserted.
Software Constraints
Before an EPP cycle is executed, the software must ensure that the control register bit PCD is a logic “0”
(i.e., a 04H or 05H should be written to the Control port). If the user leaves PCD as a logic “1”, and
attempts to perform an EPP write, the chip is unable to perform the write (because PCD is a logic “1”) and
will appear to perform an EPP read on the parallel bus, no error is indicated.
EPP 1.9 Write
The timing for a write operation (address or data) is shown in timing diagram EPP Write Data or Address
cycle. The chip inserts wait states into the LPC I/O write cycle until it has been determined that the write
cycle can complete. The write cycle can complete under the following circumstances:
1.
2.
Write Sequence of Operation
1.
2.
3.
4.
5.
6. a)
If the EPP bus is not ready (nWAIT is active low) when nDATASTB or nADDRSTB goes active then
the write can complete when nWAIT goes inactive high.
If the EPP bus is ready (nWAIT is inactive high) then the chip must wait for it to go active low before
changing the state of nDATASTB, nWRITE or nADDRSTB. The write can complete once nWAIT is
determined inactive.
The host initiates an I/O write cycle to the selected EPP register.
If WAIT is not asserted, the chip must wait until WAIT is asserted.
The chip places address or data on PData bus, clears PDIR, and asserts nWRITE.
Chip asserts nDATASTB or nADDRSTRB indicating that PData bus contains valid information, and the
WRITE signal is valid.
Peripheral deasserts nWAIT, indicating that any setup requirements have been satisfied and the chip
may begin the termination phase of the cycle.
The chip deasserts nDATASTB or nADDRSTRB, this marks the beginning of the termination phase.
If it has not already done so, the peripheral should latch the information byte now.