C8051F560-TB Silicon Laboratories Inc, C8051F560-TB Datasheet - Page 195

BOARD PROTOTYPE W/C8051F560

C8051F560-TB

Manufacturer Part Number
C8051F560-TB
Description
BOARD PROTOTYPE W/C8051F560
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheet

Specifications of C8051F560-TB

Contents
Board
Processor To Be Evaluated
C8051F56x
Processor Series
C8051F56x
Interface Type
USB
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
1.8 V to 5.25 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
C8051F55x, C8051F56x, C8051F57x
For Use With
336-1691 - KIT DEVELOPMENT FOR C8051F560
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1694
20.3. LIN Master Mode Operation
The master node is responsible for the scheduling of messages and sends the header of each frame con-
taining the SYNCH BREAK FIELD, SYNCH FIELD, and IDENTIFIER FIELD. The steps to schedule a mes-
sage transmission or reception are listed below.
1. Load the 6-bit Identifier into the LIN0ID register.
2. Load the data length into the LIN0SIZE register. Set the value to the number of data bytes or "1111b" if
3. Set the data direction by setting the TXRX bit (LIN0CTRL.5). Set the bit to 1 to perform a master
4. If performing a master transmit operation, load the data bytes to transmit into the data buffer (LIN0DT1
5. Set the STREQ bit (LIN0CTRL.0) to start the message transfer. The LIN controller will schedule the
This code segment shows the procedure to schedule a message in a transmission operation:
the data length should be decoded from the identifier. Also, set the checksum type, classic or
enhanced, in the same LIN0SIZE register.
transmit operation, or set the bit to 0 to perform a master receive operation.
to LIN0DT8).
message frame and request an interrupt if the message transfer is successfully completed or if an error
has occurred.
LIN0ADR
LIN0DAT
LIN0ADR
LIN0DAT
LIN0ADR
LIN0DAT
LIN0ADR
for (i=0; i<8; i++)
{
}
LIN0ADR
LIN0DAT
LIN0DAT = i + 0x41;
LIN0ADR++;
|= 0x20;
= ( LIN0DAT & 0xF0 ) | 0x08;
= 0x00;
= 0x08;
= 0x01;
= 0x08;
= 0x0E;
= 0x11;
= 0x0B;
Table 20.3. Autobaud Parameters Examples
System Clock (MHz)
22.1184
11.0592
12.25
24.5
25
24
16
12
8
// Point to Data buffer first byte
// Load the buffer with ‘A’, ‘B’, ...
// Increment the address to the next buffer
// Point to LIN0CTRL
// Start Request
// Point to LIN0CTRL
// Select to transmit data
// Point to LIN0ID
// Load the ID, in this example 0x11
// Point to LIN0SIZE
Rev. 1.1
Prescaler
// Load the size with 8
1
1
1
1
1
0
0
0
0
C8051F55x/56x/57x
Divider
312
306
300
276
200
306
300
276
200
195

Related parts for C8051F560-TB