C8051F560-TB Silicon Laboratories Inc, C8051F560-TB Datasheet - Page 287

BOARD PROTOTYPE W/C8051F560

C8051F560-TB

Manufacturer Part Number
C8051F560-TB
Description
BOARD PROTOTYPE W/C8051F560
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheet

Specifications of C8051F560-TB

Contents
Board
Processor To Be Evaluated
C8051F56x
Processor Series
C8051F56x
Interface Type
USB
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
1.8 V to 5.25 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
C8051F55x, C8051F56x, C8051F57x
For Use With
336-1691 - KIT DEVELOPMENT FOR C8051F560
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1694
26.4. Watchdog Timer Mode
A programmable watchdog timer (WDT) function is available through the PCA Module 5. The WDT is used
to generate a reset if the time between writes to the WDT update register (PCA0CPH5) exceed a specified
limit. The WDT can be configured and enabled/disabled as needed by software.
With the WDTE bit set in the PCA0MD register, Module 5 operates as a watchdog timer (WDT). The Mod-
ule 5 high byte is compared to the PCA counter high byte; the Module 5 low byte holds the offset to be
used when WDT updates are performed. The Watchdog Timer is enabled on reset. Writes to some
PCA registers are restricted while the Watchdog Timer is enabled. The WDT will generate a reset
shortly after code begins execution. To avoid this reset, the WDT should be explicitly disabled (and option-
ally re-configured and re-enabled if it is used in the system).
26.4.1. Watchdog Timer Operation
While the WDT is enabled:
While the WDT is enabled, writes to the CR bit will not change the PCA counter state; the counter will run
until the WDT is disabled. The PCA counter run control bit (CR) will read zero if the WDT is enabled but
user software has not enabled the PCA counter. If a match occurs between PCA0CPH5 and PCA0H while
the WDT is enabled, a reset will be generated. To prevent a WDT reset, the WDT may be updated with a
write of any value to PCA0CPH5. Upon a PCA0CPH5 write, PCA0H plus the offset held in PCA0CPL5 is
loaded into PCA0CPH5 (See Figure 26.11).
PCA0CPLn
PCA counter is forced on.
Writes to PCA0L and PCA0H are not allowed.
PCA clock source bits (CPS[2:0]) are frozen.
PCA Idle control bit (CIDL) is frozen.
Module 5 is forced into software timer mode.
Writes to the Module 5 mode register (PCA0CPM5) are disabled.
Write to
Reset
PCA0CPHn
Write to
0
1
ENB
ENB
W
M
P
1
6
n
1
E
C
O
M
n
PCA0CPMn
C
A
P
P
n
0 0 x 0
C
A
P
N
n
M
A
T
n
PCA Timebase
O
G
T
n
W
M
P
n
E
C
C
F
n
x
Figure 26.10. PCA 16-Bit PWM Mode
Enable
PCA0CPHn
PCA0H
16-bit Comparator
Rev. 1.1
PCA0CPLn
PCA0L
Overflow
C8051F55x/56x/57x
match
S
R
SET
CLR
Q
Q
CEXn
Crossbar
Port I/O
287

Related parts for C8051F560-TB