R88A-CSU015C Omron, R88A-CSU015C Datasheet - Page 111

no-image

R88A-CSU015C

Manufacturer Part Number
R88A-CSU015C
Description
ABSOLUTE ENCODER CABLE,15M
Manufacturer
Omron
Datasheet

Specifications of R88A-CSU015C

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Design and Installation
j Lithium Battery (Recommended Products)
With an absolute encoder, a battery must be used in order to retain position data when the power is
turned OFF.
Note 1. When power is turned OFF internally at the Position Driver, the battery voltage is not moni-
Note 2. Use one battery for one Position Driver. (The estimated battery service life is calculated based
Note 3. The Toshiba lithium battery does not have a connector for BAT connections. It is necessary to
j Replacing the Battery
The following method can be used to replace the battery while retaining the absolute encoder’s rotation
data.
Note 1. After step 1 above has been implemented, the encoder will operate normally even with the
Note 2. While replacing the battery, be careful not to short-circuit the plus and minus terminals.
Note 3. When disconnecting the lead wires, disconnect the plus and minus terminals separately. Dis-
Note 4. Be sure to use the prescribed method for disposing of used batteries. In particular, do not un-
j Setting up the Absolute Encoder
Setup is required to set the amount of machine rotation to zero for trial operation of the Servomotor or
when the absolute encoder has been left disconnected from the battery for more than two days. (This is
because the voltage of the capacitor inside the absolute encoder will drop if a battery is left unconnected
for more than two days, possibly interfering with the proper operation of internal elements.)
2-88
Toshiba
OMRON (made by
Hitachi Maxell)
1. Turn ON the Position Driver’s power supply and leave it ON for three minutes. This will charge the
2. Turn OFF the Position Driver’s power supply and leave it OFF while replacing the battery. Connect
capacitor in the encoder.
the battery between pins 2 and 3 of the Position Driver’s BAT connector (CN6).
Maker
tored. Be careful not to let the voltage drop below 2.8 V. If necessary, install a battery voltage-
drop detection circuit or a monitor in the system.
on this condition.)
separately purchase and attach a connector for BAT connections.
battery removed for up to two days (at 0 C to 40 C).
connecting them at the same time can cause them to short-circuit and create sparks.
der any circumstances dispose of them in a fire. Doing so may cause them to explode.
ER6V
3G2A9-BAT08
Model
3.6 V
3.6 V
Voltage
2,000 mA h
1,650 mA h
Electrical capacity
Approx. 10 years
Approx. 7 years
Estimated service life
Chapter 2