R88A-CSU015C Omron, R88A-CSU015C Datasheet - Page 128

no-image

R88A-CSU015C

Manufacturer Part Number
R88A-CSU015C
Description
ABSOLUTE ENCODER CABLE,15M
Manufacturer
Omron
Datasheet

Specifications of R88A-CSU015C

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Operation
j H Parameters (HP-33, HP-46)
3-16
25
26
28
29
30
31
33
46
UP-
HP-
No.
No.
Monitor output
Motor rotation
direction
Brake ON
speed
Motor test
speed
External
regeneration
resistance
value
External
regeneration
resistance
capacity
Load rate time
In-position timer
Name
Name
---
---
0.1%
1 r/min
0.1
0.01 kW
Min. unit
1 s
3.2 ms
Min.
unit
1 to 60
3.2 to
320.0
Setting
range
000 to
011
0, 1
0.0 to
100.0
1 to
8,000
0.0 to
100.0
0.00 to
327.67
Setting
range
30
3.2
010
0
1.0
50
0.0
0.00
Factory
setting
Factory
setting
Specifies interval for effective load
factor calculation to value obtained
from machine cycle time multiplied
by an integer.
Specifies minimum positioning
completion ON time and minimum
ready signal OFF time.
Specifies monitor output function.
0
Specifies motor rotation direction.
0: Forward rotation
1: Reverse direction
Specifies r/min to turn OFF break
output in on-hold brake mode.
Specifies rate based on rated motor
r/min as 100%.
* The brake may be damaged if the
Specifies r/min for motors for test-
ing.
* When testing a motor, make sure
Specifies the regeneration
absorption resistance value ( )
* Only valid for FND-X50H- .
* When using an OMRON External
Specifies the regeneration
absorption resistance capacity
(kW).
* Only valid for FND-X50H- .
on-hold brake mode is selected
for motors rotating at high speed.
that the set value is less than the
rated motor r/min.
Regeneration Resistor, set to 30.0
( ).
Positive voltage
0: Not reversed
1: Reversed
Speed/Current selection
0: Current
1: Speed
Explanation
Explanation
Chapter 3
No
No
No
No
Yes
Yes
No
No
Re-power
required?
Re-power
required?