R88A-CSU015C Omron, R88A-CSU015C Datasheet - Page 194

no-image

R88A-CSU015C

Manufacturer Part Number
R88A-CSU015C
Description
ABSOLUTE ENCODER CABLE,15M
Manufacturer
Omron
Datasheet

Specifications of R88A-CSU015C

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Application
j Monitor Details
Note In the motor speed, present value, position deviation, mechanical speed, and motor current moni-
r
A’
A
C’
C
E’
E
P’
P
F’
F
cF
cc
L
bL
oL
d
rL
Display
toring displays, the respective display will flash if the value is negative. (The numeric portion will
not flash.)
Motor speed
Present value
(leftmost digits)
Present value
(rightmost digits)
Reference value
(leftmost digits)
Reference value
(rightmost digits)
Position deviation
(leftmost digits)
Position deviation
(rightmost digits)
(Not used.)
(Not used.)
Mechanical speed
(leftmost digits)
Mechanical speed
(rightmost digits)
(Not used.)
(Not used.)
Motor current
Effective load factor
Electrothermal value
Electrical angle
Regenerative
absorption rate
Monitored item
r/min
Mechanical axis
movement
movement
Mechanical axis
movement
movement
Pulse
---
Mechanical axis
movement per second
movement er second
---
---
A
%
%
deg
%
0–P
Unit
Displays the actual rotation speed of the motor
shaft.
Calculates and displays the present value of the
mechanical axis based on feedback from the
mechanical axis based on feedback from the
motor sensor.
Displays the mechanical axis position
referenced by the Position Driver.
referenced by the Position Driver.
Displays the deviation of the present value from
the reference value with encoder/resolver
the reference value with encoder/resolver
resolution.
---
Calculates and displays the movement speed of
the mechanical axis based on feedback from
the mechanical axis based on feedback from
the motor sensor.
---
---
Displays the output current to the motor.
Displays the effective load factor with respect to
the motor’s rated current value.
Effective load factor = (output current effective
value) / (motor’s rated current)
Effective values are calculated at the time
interval set for HP-33 (load factor time
constant).
Calculates the motor’s heat generation from the
output current and displays it as a percentage
of the heat generation in rated operation. (When
the power is turned ON, 90 [%] is displayed.) If
this value exceeds 110 [%], an A.L17 (motor
overload) alarm will be detected.
Displays the motor’s electrical angle (0.0 to
360.0).
When a Regeneration Resistor is connected,
this monitor item displays the regenerative
absorption current as a percentage of the
motor’s rated current.
Explanation
Chapter 4
4-3