R88A-CSU015C Omron, R88A-CSU015C Datasheet - Page 181

no-image

R88A-CSU015C

Manufacturer Part Number
R88A-CSU015C
Description
ABSOLUTE ENCODER CABLE,15M
Manufacturer
Omron
Datasheet

Specifications of R88A-CSU015C

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Operation
In this auto-tuning example, it is assumed that the reciprocating rotation range is set to 5 (revolutions),
the target response frequency is set to 50 (Hz), and the maximum rotation speed is set to 2,000 (r/min).
Operating Procedure Example
Display example
Press the Mode Key to enter Monitor Mode.
Hold down the Increment Key, Decrement Key, and Data Key simultaneously for at
least five seconds to enter System Check Mode.
Press the Shift Key twice to bring up the auto-tuning display (reciprocating rotation
range).
Press the Increment Key to display the reciprocating rotation range data.
Press the Data Key and Shift Key to enable the data to be changed. (The digit that
can be changed will flash.)
Use the Increment Key, the Decrement Key, and the Shift Key to change the
setting to “5.”
Press the Data Key to save the new setting.
Press the Increment Key to bring up the target response frequency display.
Press the Increment Key to display the target response frequency data.
Press the Data Key and Shift Key to enable the data to be changed. (The digit that
can be changed will flash.)
Use the Increment Key, the Decrement Key, and the Shift Key to change the
setting to “50.”
Press the Data Key to save the new setting.
Press the Increment Key to bring up the maximum rotation speed display.
Press the Increment Key to display the maximum rotation speed data.
Press the Data Key and Shift Key to enable the data to be changed. (The digit that
can be changed will flash.)
Use the Increment Key, the Decrement Key, and the Shift Key to change the
setting to “2000.”
Press the Data Key to save the new setting.
Press the Increment Key to bring up the auto-tuning display (reciprocating rotation
range).
Press the Data Key and the Increment Key to execute auto-tuning. (The display
will flash while the motor is operating.)
When the display stops flashing it indicates that the auto-tuning operation is
completed.
Double-click the Mode Key to return to Monitor Mode.
Key operation
Chapter 3
3-69

Related parts for R88A-CSU015C